7. COMMUNICATION THAT DO NOT REQUIRE
THE SEQUENCE PROGRAM
7.1.13
InitiateDownloadSequence, DownloadSegument, and TerminateDownloadSequence are used to batch
download program, parameter, comment, extension comment, device, and special functions module
buffer memory data. The sequential processing flow is shown below.
The program, parameter, comment, extension comment, device, and special functions module buffer
memory must be defined in the OD as domains using the SW0IX-PROFPE.
The same domain cannot be downloaded from multiple connections at the same time. In addition, a
domain that is being uploaded cannot be downloaded. When the PC CPU is running only the device or
buffer memory download can be conducted.
[Parameters required by the client]
• Access Specification
[Server (AJ71PB96F/A1SJ71PB96F) answer parameters]
None
Initiating program, parameter, and comment, device buffer memory
download (InitiateDownloadSequence: Server)
Server
TerminateDownloadSequence.reques
TerminateDownloadSequence.response
Specify the Index and Name of the domain to be registered in the OD.
Access Specification
Index
Variable Name
InitiateDownloadSequence.reques
InitiateDownloadSequence.response
DownloadSegument.reques
DownloadSegument.response
MoreFollows=True
. . .
(Repeat)
DownloadSegument.reques
DownloadSegument.response
MoreFollows=False
FinalResult
Setting value
Domain Index
Domain Name
7-17
MELSEC-A