Burkert 8750 Quick Start Manual page 24

Flow controller
Table of Contents

Advertisement

4
3
4
3
Fig. 13: Connection with PROFIBUS DP
Socket M12, 5-pole (bus connection)
Pin
Signal
1
VP+5
2
RxD/TxD-N
3
DGND
4
RxD/TxD-N
5
Shielding
Tab. 10: Socket M12, 5-pole (bus connection)
24
Socket M12, 5-pole
1
5
(inversely coded)
2
(PROFIBUS DP)
3
Circular plug M8, 4-pole
1
Pressure sensor P1, P2
2
2
Circular plug M12, 4-pole
1
Operating voltage
4
TE connection
english
Typ 8750
Electricalinstallation
Circular plug M8, 4-pole (pressure sensor)
Pin
Wire color
Assignment
1
brown
+ 24 V pressure sensor power supply
2
white
4 – 20 mA output from pressure sensor
Tab. 11: Circular plug M8, 4-pole (pressure sensor)
Circular plug M12, 4-pole (operating voltage)
Pin
Wire color
6)
Assignment
1
brown
Operating voltage +
3
blue
Operating voltage
Tab. 12: Circular plug M12, 4-pole (operating voltage)
The indicated colors refer to the connecting cable available as an
6)
accessory (918038).
24 V DC
GND

Advertisement