Transportation; Stationary Use; Thermal Limitations; Material Content Compliance - Nokia 7368 ISAM ONT G-240W-C Product Manual

Hide thumbs Also See for 7368 ISAM ONT G-240W-C:
Table of Contents

Advertisement

ETSI environmental and CRoHS guidelines
3.3.3
According to EN 300-019-1-2 - Class 2.3, transportation of the OLT equipment must
be in packed, public transportation with no rain on packing allowed.
3.3.4
According to EN 300-019-1-3 - Class 3.1/3.2/3.E, stationary use of OLT equipment
must be in a temperature-controlled location, with no rain allowed, and with no
condensation allowed.
3.3.5
When the OLT is installed in the CO or CEV, install air filters on the P-OLT. The
thermal limitations for OLT operation in a CO or CEV are:
3.3.6
European Union (EU) Directive 2002/95/EC, "Restriction of the use of certain
Hazardous Substances" (RoHS), restricts the use of lead, mercury, cadmium,
hexavalent chromium, and certain flame retardants in electrical and electronic
equipment. This Directive applies to electrical and electronic products placed on the
EU market after 1 July 2006, with various exemptions, including an exemption for
lead solder in network infrastructure equipment. Nokia products shipped to the EU
after 1 July 2006 comply with the EU RoHS Directive.
Nokia has implemented a material/substance content management process. The
process is described in: Nokia process for ensuring RoHS Compliance
(1AA002660031ASZZA). This ensures compliance with the European Union
Directive 2011/65/EU on the Restriction of the Use of Certain Hazardous Substances
in Electrical and Electronic Equipment (RoHS2). With the process equipment is
assessed in accordance with the Harmonised Standard EN50581:2012 (CENELEC)
on Technical documentation for the assessment of electrical and electronic products
with respect to the restriction of hazardous substances.
30
R05.05.01 | December 2016 | 3FE 46690 AAAA TCZZA | Edition 01

Transportation

Stationary use

Thermal limitations

operating temperature: 5°C to 40°C (41°F to 104°F)
short-term temperature: –5°C to 50°C (23°F to 122°F)
operating relative humidity: 5% to 85%
short-term relative humidity: 5% to 95%, but not to exceed 0.024 kg of water/kg

Material content compliance

7368 ISAM ONT G-240W-C Product Guide
Edition 01
Issue: 01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents