ETSI environmental and CRoHS guidelines
4.3.1
See the ONT technical specification documentation for more information about
4.3.2
According to ETS 300-019-1-1 - Class 1.1, storage of OLT equipment must be in
4.3.3
According to EN 300-019-1-2 - Class 2.3, transportation of the ONT equipment must
4.3.4
According to EN 300-019-1-3 - Class 3.1/3.2/3.E, stationary use of ONT equipment
4.3.5
When the ONT is installed in the CO or CEV, install air filters on the OLT. The thermal
34

ONT environmental requirements

temperature ranges.

Storage

Class 1.1, weather-protected, temperature-controlled locations.

Transportation

be in packed, public transportation with no rain on packing allowed.

Stationary use

must be in a temperature-controlled location, with no rain allowed, and with no
condensation allowed.

Thermal limitations

limitations for ONT operation in a CO or CEV are:
operating temperature: 5° C to 40° C (41° F to 104° F)
short-term temperature: –5° C to 50° C (23° F to 122° F)
operating relative humidity: 5% to 85%
short-term relative humidity: 5% to 95%, but not to exceed 0.024 kg of water/kg
3FE-48009-AAAA-TCZZA
7368 ISAM ONT G-240W-J Product Guide
Issue: 01