Removing/Inserting Sewing Head - Pfaff 3588-05/020 Instruction Manual

Table of Contents

Advertisement

13

Removing/inserting sewing head

.04
4
Fig. 13 - 01
● To remove the sewing head, remove the protective cover 1 (screws 2).
● Remove the cover plate 3 (screws 4; 6 screws altogether)
● Unplug pneumatic power supply 5 and electrical power supply 6.
● Unhook catch 7 and fold down sewing head.
● Remove V-belt from belt pulley on motor.
● Lift sewing head and remove from its bracket.
● Remove the ground cable of the sewing head.
● To insert the sewing head, carry out the steps above in reverse.
Turn off compressed air!
Switch off main switch and ensure that it cannot be turned back on accidentally.
3
5
6
Adjustment
1
7
2
91