Label
Rate Limiter ID
Rate
4.1.10.3.3 ACL Configuration
Configure an ACE (Access Control Entry) on this page.
An ACE consists of several parameters. These parameters vary according to the frame type
that you select. First select the ingress port for the ACE, and then select the frame type.
Different parameter options are displayed depending on the frame type that you selected.
A frame that hits this ACE matches the configuration that is defined here.
Label
Ingress Port
Frame Type
ORing Industrial Networking Corp
DGS-7084GCP-AIO_S SERIES User's Manual
Description
The rate limiter ID for the settings contained in the same row.
The rate unit is packet per second (pps), configure the rate as 1, 2, 4,
8, 16, 32, 64, 128, 256, 512, 1K, 2K, 4K, 8K, 16K, 32K, 64K, 128K,
256K, 512K, or 1024K.
The 1 kpps is actually 1002.1 pps.
Description
Select the ingress port for which this ACE applies.
Any: The ACE applies to any port.
Port n: The ACE applies to this port number, where n is the number
of the switch port.
Policy n: The ACE applies to this policy number, where n can range
from 1 through 8.
Select the frame type for this ACE. These frame types are mutually
exclusive.
Any: Any frame can match this ACE.
Ethernet Type: Only Ethernet Type frames can match this ACE. The
IEEE 802.3 descripts the value of Length/Type Field specifications
should be greater than or equal to 1536 decimal (equal to 0600
84