Page 1
- Power Supply 1: 12VDC or 24VDC @ 6 amp. - Power Supply 1: 24VDC @ 10 amp. - Power Supply 2: 12VDC @ 10 amp. - Power Supply 2: 24VDC @ 10 amp. Altronix Corp. 140 58th St. Brooklyn, NY More than just power. Rev. MFE051313...
Page 2
MaximalFE Overview: Maximal Expandable Power Systems provide system designers and installers with optimum power choices and the high- est levels of versatility. They provide 12VDC, 24VDC, or 12VDC and 24VDC simultaneously via two (2) single output power supply/chargers. Includes AC fail, low battery, and battery presence monitoring. Enclosure facilitates up to four (4) 12VDC/12AH batteries.
Page 3
MaximalFE Series Configuration Chart: Nominal DC Output Voltage Options Power Supply 1 Power Supply 2 [DC] [AUX] [DC] [AUX] Altronix Model Number eFlow4NB eFlow4NB 10.1- 10.05- 10.1- 10.05- 13.2 ---------- 13.2 ---------- 13.2 ---------- 13.2 ---------- Maximal11FE 4A + 4A --- 2 2 7 7.5A/32V...
4. Measure output voltage before connecting devices. This helps avoiding potential damage. 5. Connect devices or Altronix sub-assembly modules to be powered to the terminals marked [-- DC +] (Fig. 2, pg. 7). For auxiliary device connection, this output will not be affected by Low Power Disconnect or Fire Alarm Interface.
Power Supply Board Terminal Identification: Terminal Function/Description Legend L, G, N Connect 120VAC 60Hz to these terminals: L to hot, N to neutral. Do not use the [G] terminal + DC – Refer to MaximalFE Series Configuration Chart, pg. 3. Trigger EOL Fire Alarm Interface trigger input from a short or FACP.
Power Supply Board LED Diagnostics: Green (DC) Green (AC/AC1) Power Supply Status Normal operating condition. Loss of AC. Stand-by battery supplying power. No DC output. Loss of AC. Discharged or no stand-by battery. No DC output. Power Supply Board Output Voltage Settings: Fig.
Page 7
Fig. 2 Tamper Switch Fig. 2a AC FAIL BAT FAIL AC DELAY SHUTDOWN 5A 250V 1 min. enable TRIGGER EOL NC C NO NC C NO + AUX – 2 hr. disable SUPERVISED RESET Line Neutral Sentrol model # 3012 Tamper Switch or equivalent Enclosure...
NEC Power-Limited Wiring Requirements: Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25” away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits. One such example of this is shown below.
Enclosure Dimensions (H x W x D approximate) 26” x 19” x 6.25” (660.4mm x 482.6mm x 158.75mm) 19” (482.6mm) 2” 2” 4” 7” 4” (50.8mm) (50.8mm) (101.6mm) (177.8mm) (101.6mm) 6.25” (158.75mm) 19” 1.25” (482.6mm) 1.25” 0.85” 0.85” (31.75mm) 8.9” 8.4”...
Page 10
Notes: Maximal Expandable Power Systems - 10 -...
Page 11
Notes: - 11 - Maximal Expandable Power Systems...
Page 12
Notes: Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. MEMBER IIMaximalFE Series G20O...