152 Multiplexing
Table 5
Allison transmission programmed parameters (cont'd)
Maximum output speed for auto-neutral (if present)
Output speed indicator A to turn on
Output speed indicator A to turn off
a.
The value is adjusted so it corresponds with the vehicle speed in mph. It may vary according to the differential gear ratio and tire size.
Table 6
Allison wires to be enabled
Pack enable
Input
PTO
Output
PTO
Output neutral indicator – PTO
Auto-neutral pack enable (if present)
Output speed indicator A
To tap into the TCM, Labrie uses the following wires on the Allison connector:
Table 7
Input
Wire #
117
143
142
Parameters
Wires
enable
enable
Description
Pump pack enable
P
enable
TO
Auto-neutral pack input
Wire # (WTEC IV)
117
143
130
145
142
105
Active when the brakes are used, and when the PTO and
auto-neutral switches are on (ground signal).
Active when the PTO switch is on (+12 ­V signal).
Active when the brakes are used, and when the PTO and
auto-neutral switches are on (ground signal).
r.p.m.
500 (7 mph)
160 (2 mph)
110 (1.2 mph)
State