5 — PROGRAMMABLE PARAMETERS:
PARAMETER
Off / Swvl / Seat
Active Low
Charger inhibit
Halt Act 1 Dir-
Halt Act 1 Dir+
Halt Act 2 Dir-
Halt Act 2 Dir+
Speed Limit
32

Multi-Function Input 3 Parameters

can be used to provide a swivel chair function (=1). Al-
Multi-Function Input 3
ternatively, it can be used to provide an appropriate speed limit when a switch
is activated (=2). Multi-Function Input 3 is at Pin 7 on the 14-pin connector;
see Figure 6, page 9.
MULTI-FUNCTION INPUT 3 MENU
RANGE
0–2
0 = Multi-Function Input 3 ignored.
1 = Provides swivel chair function. This is used specifically for
chairs with seats that can rotate from rear drive to front drive.
With this parameter set to 1, the Profile will switch from
Profile 1 to Profile 2 when Input 3 is active (see next parameter).
In addition, the motor directions will be inverted and swapped.
The MyChair setting is ignored when in swivel mode.
2 = Sets the speed limit specified below when Input 3 is active.
On/Off
When programmed On, the Inhibit and Speed Limit functions are
active when the switch is closed (pulled low to B-); when programmed
Off, these functions are active when the switch is open.
On/Off
Enables Input 3 to be used with an on-board charger. The charger will
pull the inhibit active during charging, which will inhibit drive, light the
charger and battery icons in the handcontrol display, and engage the
EM brake.
On/Off
Actuator 1 will be halted in the negative direction.
On/Off
Actuator 1 will be halted in the positive direction.
On/Off
Actuator 2 will be halted in the negative direction.
On/Off
Actuator 2 will be halted in the positive direction.
0–100 %
Sets the speed limit that will be in effect when Off/Swvl/Seat = 2
and Input 3 is active (see Active Low parameter).
DESCRIPTION
Curtis enAble
40 Manual,
®
Rev. E