Specifications
Digital outputs
Programmable digital/pulse outputs
Terminal number
Voltage level at digital/frequency output
Max. output current (sink or source)
Max. load at frequency output
Max. capacitive load at frequency output
Minimum output frequency at frequency output
Maximum output frequency at frequency output
Accuracy of frequency output
Resolution of frequency outputs
1) Terminal 27 and 29 can also be programmed as input.
The digital output is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
Control card, 24 V DC output
Terminal number
Max. load
The 24 V DC supply is galvanically isolated from the supply voltage (PELV), but has the same potential as the analog and digital
inputs and outputs.
Relay outputs
Programmable relay outputs
Relay 01 and 02
Max. terminal load (AC-1)
8
8
Max. terminal load (AC-15)
Max. terminal load (DC-1)
Max. terminal load (DC-13)
Max. terminal load (AC-1)
Max. terminal load (AC-15)
Max. terminal load (DC-1)
Min. terminal load on 01-03 (NC), 01-02 (NO)
1) IEC 60947 t 4 and 5
The relay contacts are galvanically isolated from the rest of the circuit by reinforced isolation (PELV).
Control card, +10 V DC output
Terminal number
Output voltage
Max. load
The 10 V DC supply is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
Control characteristics
Resolution of output frequency at 0-500 Hz
System response time (terminals 18, 19, 27, 29, 32, 33)
Speed control range (open loop)
Speed accuracy (open loop)
All control characteristics are based on a 4-pole asynchronous motor
40
®
VLT
AutomationDrive FC 360 Quick Guide
1)
on 01-02/04-05 (NO) (Resistive load)
on 01-02/04-05 (NO) (Inductive load @ cosφ 0.4)
1)
1)
on 01-02/04-05 (NO) (Resistive load)
1)
on 01-02/04-05 (NO) (Inductive load)
1)
on 01-03/04-06 (NC) (Resistive load)
on 01-03/04-06 (NC) (Inductive load @ cosφ 0.4)
1)
1)
on 01-03/04-06 (NC) (Resistive load)
MG06A302 - VLT
01-03 (NC), 01-02 (NO), 04-06 (NC), 04-05 (NO)
30-4000 RPM: Maximum error of ±8 RPM
®
is a registered Danfoss trademark
27, 29
0-24 V
40 mA
1 kΩ
10 nF
4 Hz
32 kHz
Max. error: 0.1 % of full scale
10 bit
100 mA
250 V AC, 3 A
250 V AC, 0.2 A
30 V DC, 2 A
24 V DC, 0.1 A
250 V AC, 3 A
250 V AC, 0.2 A
30 V DC, 2 A
24 V DC 10 mA, 24 V AC 20 mA
10.5 V ±0.5 V
15 mA
± 0.003 Hz
≤ 2 ms
1:100 of synchronous speed
2
1)
12
2
50