Junction Box (Model Jb-Mpd); Iecex (-X Model); Transmitter (Aluminum); Transmitter (Stainless Steel) - Emerson Net Safety Millennium Reference Manual

Apm oil mist detector air particle monitor
Hide thumbs Also See for Net Safety Millennium:
Table of Contents

Advertisement

9.2.3

Junction box (Model JB-MPD)

0575
-55 °C ≤ Ta ≤ +85 °C IP67
FM07ATEX0044
9.3

IECEx (-X model)

9.3.1

Transmitter (aluminum)

Ex d IIB+H
-40 °C ≤ Ta ≤ +85 °C
Certificate Number: IECEx DNV 12.0014
IEC 60079-0: 2007-10/IEC 60079-1:2007-04
9.3.2

Transmitter (stainless steel)

Ex d IIB+H
-55 °C ≤ Ta ≤ +85 °C
Certificate Number: IECEx FMG 13.0035X
IEC 60079-0:2011/IEC 60079-1:2007/IEC 60529:2001
Consult the manufacturer if dimensional information on the flameproof joints is necessary.
9.3.3
APM Sensor
Ex d IIB+H
-40 °C ≤ Ta ≤ +75 °C
Certificate Number: IECEx SIR 17.0061X
9.3.4
Junction Box (Model JB-MPD)
Ex d IIB+H
Certificate Number: IECEx FMG 14.0009X
II 2 G Ex d IIB+H
T5
2
T5 Gb
2
T5 Gb
2
T5 Gb IP65
2
T5 Gb
2
Certifications