3
3.1
iCR70 Keyboard
iCR70 key functions
and LED behaviour
30
User Interface
Keyboard
a
b
c
d
16069_001
☞
The following description of key functions and LED behaviours applies
to the iCR70 being connected to a field controller.
Key functions
LOCK
Press to start prism search and lock onto prism.
•
If already locked: Press to unlock from prism.
•
MEAS
Depending on the currently active settings:
Press to start a measurement or to store a measurement.
ON/OFF
•
Press for 2 s to turn on the instrument.
Press and hold for more than 2 s to shut down the instru-
•
ment.
•
Press and hold for more than 5 s to reset the sensor.
Press and hold for more than 8 s to do a hard shutdown.
•
COM
•
To toggle through the communication modes, press the key
repeatedly.
Communication modes:
-
RS232
Bluetooth
-
Long-range Bluetooth
-
•
If a connection is already established, press and hold for 2 s
to disconnect.
LED behaviours
LOCK
Off: Prism not locked.
•
Solid green: Prism found and locked.
•
MEAS
•
Off: No active measurement.
Solid green: Measurement is executed.
•
ON/OFF
Off: No active measurement.
•
Solid red after switching on: Instrument is booting.
•
Solid green/yellow/red: Indicator for the battery status.
•
-
Green: more than 40% of battery charge remaining.
Yellow: more than 20% of battery charge remaining.
-
Red: remaining battery charge is very low.
-
•
Flashing green: Instrument is shutting down.
e
f
g h
a
b
c
d
e
f
g
h
LOCK key
LED for locking status
MEAS key
LED for measurement status
LED for communication status
LED for power status
ON/OFF key
COM key
User Interface