Technical Data; Angle Measurement; Distance Measurement With Reflectors - Leica iCON iCR70 User Manual

Table of Contents

Advertisement

7
7.1
Accuracy
Characteristics
7.2
Range
Atmospheric condi-
tions

Technical Data

Technical Data

Angle Measurement

Available angular accuracies
["]
2
5
Absolute, continuous, diametric.

Distance Measurement with Reflectors

Reflector
Standard prism
(GPR1)
Three standard
prisms
(GPR1)
360° prism
(GRZ4, GRZ122)
360° Mini prism
(GRZ101)
Mini prism
(GMP101)
Reflector tape
GZM31)
60 mm x 60 mm
Shortest measuring distance:
Range
A
B
C
Measurements can be made to reflector tapes over the entire range without
external ancillary optics.
Standard deviation
Hz, V
ISO 17123-3
[mgon]
0.6
1.5
Range A
Range B
[m]
[ft]
[m]
1800
6000
3000
2300
7500
4500
800
2600
1500
450
1500
800
800
2600
1200
150
500
250
1.5 m
Description
Strong haze, visibility 5km; or strong sunlight, severe
heat shimmer
Light haze, visibility about 20km; or moderate sun-
light, slight heat shimmer
Overcast, no haze, visibility about 40km; no heat
shimmer
Range C
[ft]
[m]
[ft]
10000
3500
12000
14700
5400
17700
5000
2000
7000
2600
1000
3300
4000
2000
7000
800
250
800
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icon icr80

Table of Contents