Mix DDC

To update DDC information based on resolution characteristics common to the monitors connected to the Local and Remote units,
press <N> to enter DDC information from both. The CapsLock LED will illuminate solid, the NumLock and ScrollLock LEDs will
be OFF . Press the < Left Arrow> or <Right Arrow> key to cause DDC information to be updated. When the update is
complete (approximately seven seconds), the unit will return to General Video Quality Adjustment mode (the three keyboard LEDs
will blink at the same time).
Keyboard LED Indications
Adjustment Mode
General Video Quality
DDC

Reset Defaults

Press the<A> key (while in Command Mode) to reset the fine tuning to default settings. Once settings have been reset, the user
will automatically return to General Video Quality Adjustment mode.

Exit Command Mode

Press the <Esc> key to exit Command Mode and return to normal operation.
LED state.
Note: Command Mode will time out and return to normal operation on its own after 7 seconds when operated from the
Local keyboard.
FYI: Video quality will be limited by several factors. Some factors include the quality and type of CAT5 cable being
used, the length of cable run, the quality of the monitor, the resolution setting of the monitor, and the quality of the video
card used in the video source.
described in this section, consider the following possible adjustments that can be made:
Improve the quality of cable used -CAT5,5e,or 6 (CAT5e unshielded (UTP) cable will provide the best
performance)
Use unshielded cable (UTP) instead of shielded cable (STP)
Shorten the length of the cable between the remote and local
Reduce the resolution setting on the monitor used
Use a higher quality video card in the video source

Other DDC Support

Automatic EDID Updates

Applicable to models without keyboard and mouse support and rackmount models (ST-C5xxxx-600M).
The 15HD connector on many models provides local video as well as DDC support. The EDID data is updated automatically at
initial power-ON or whenever a different monitor is connected to the Local Unit.
connected to the Local Unit. For that reason, it is recommended that the monitor connected to the Remote and Local Units be
the same model.
The Local Unit and the monitor must both be powered-ON prior to the CPU in order to update the EDID data.
Note: The ST-C5xxx-L-600M Local Unit will not store the EDID data. A monitor must be connected to the Local Unit each
time the CPU is power cycled in order for EDID data to remain current.
Note: When an ST-C5KVM(xx)-R-600 Remote Unit is used with an ST-C5KVM(xx)-L-600M (Rackmount Local Unit),
Automatic EDID Update will work as described above. DDC Update via Command Mode (as described on the previous
page) will not be supported at the Remote Unit.
NUM LOCK
CAPS LOCK
Blink
Blink
OFF
Solid
If the desired level of image clarity cannot be achieved by making the adjustments
18
SCROLL LOCK
Blink
OFF
All keyboard LEDs will return to current keyboard
DDC is only updated from the monitor