Hp E1328A Command Quick Reference - HP E1328A User Manual

D/a converter module
Hide thumbs Also See for E1328A:
Table of Contents

Advertisement

Command
Subsystem
n
CALibration
DISPlay
[SOURce:]
SYSTem
Chapter 5

HP E1328A Command Quick Reference

The following table summarizes SCPI Commands for the HP E1328A.
SCPI Commands Quick Reference
Command/Parameter
measured
:CURRent <
>
mode
:STATe <
>
:STATe?
measured
:VOLTage <
>
channel
:MONitor:CHANnel <
channel
:MONitor:CHANnel? <
mode
:MONitor[:STATe] <
:MONitor:STRing?
n
level
:CURRent
<
>
n
:CURRent
?
n
:FUNCtion
?
:VOLTage
n
<
level
>
n
:VOLTage
?
:ERRor?
Enters three measured values to update the
channel's stored current adjustment constant.
Selects mode to calibrated (1) or non-calibrated (0).
Returns mode channel is currently operating under.
Enters three measured values to update the
channel's stored voltage adjustment constant.
Enters the desired channel number to be viewed
>
when in monitor mode (1 to 4 or auto).
Returns the presently selected channel number to be
>
viewed when in monitor mode (1 to 4 or auto); or the
DEFault, MINimum, or MAXimum available channel
number.
Selects monitor mode to on (1) or off (0).
>
Returns the selected channel number (1 to 4),
output configuration (voltage or current), output
level, and mode (calibrated or non-calibrated).
Sets the specified channel (
current level.
Returns the current level the specified channel (
is currently set to output.
Returns the present position of the V/I jumper in
the specified channel's (
Sets the specified channel (
voltage level.
Returns the voltage level the specified channel (
is currently set to output.
Returns the error number/message in the error queue.
HP E1328A Command Reference
Description
n
) to output the specific
n
) digital section.
n
) to output the specific
n
)
n
)
51

Advertisement

Table of Contents
loading

Table of Contents