Scpi Command Quick Reference - HP VXI E1476A User's Manual And Programming Manual

64-channel, 3-wire multiplexer module
Table of Contents

Advertisement

SCPI Command Quick Reference

Command
ABORt
'
ARM
:COUNt <number>
:COUNt? [MIN|MAX]
DISPlay
:MONitor:CARD <number> | AUTO
:MONitor:CARD?
:MONitor[:STATe] <mode>
:MONitor[:STATe]?
INITiate
:CONTinuous ON | OFF
:CONTinuous?
[:IMMediate]
OUTPut
:ECLTrgn[:STATe] ON | OFF | 1 | 0
:ECLTrgn[:STATe]?
[:EXTernal][:STATe] ON | OFF | 1 | 0
[:EXTernal][:STATe]?
:TTLTrgn[:STATe] ON |OFF | 1 | 0
:TTLTrgn[:STATe]?
[ROUTe:]
CLOSe <channel _list>
CLOSe? <channel _list>
OPEN <channel_list>
OPEN? <channel _list>
SCAN <channel_list>
SCAN:MODE <mode>
SCAN:MODE?
SCAN:PORT <port>
STATus
:OPERation:CONDition?
:OPERation:ENABle <unmask>
:OPERation:ENABle?
:OPERation[:EVENt]?
:PRESet
SYSTem
:CDEScription? <number>
:CPON <number> | ALL
:CTYPe? <number>
:ERRor?
TRIGger
[:IMMediate]
:SOURce BUS
:SOURce ECLTrg n
:SOURce EXTernal
:SOURce HOLD
:SOURce IMMediate
:SOURce TTLTrg n
:SOURce?
Chapter 3
The following table summarizes the SCPI commands for the HP E1476A 64-
Channel Relay Multiplexer used in a switchbox.
Abort a scan in progress.
Multiple scans per INIT command.
Query number of scans.
Selects module to be monitored.
Query the card number.
Selects monitor mode.
Query the monitor mode.
Enables/disables continuous scanning.
Query continuous scan state.
Starts a scanning cycle.
Enables/disables the specified ECL trigger line.
Query the specified ECL trigger line.
Enables/disables the "Trig Out" port on the command module.
Query the external state.
Enables/disables the specified TTL trigger line.
Query the specified TTL trigger line.
Close channel(s).
Query channel(s) closed.
Open channel(s).
Query channel(s) opened.
Define channels for scanning.
Sets scan mode to NONE, VOLT, RES, or FRES.
Query the scan mode.
Enables channel connections to the analog bus (ABUS or
NONE).
Returns contents of the Operation Condition Register.
Enables events in the Operation Event Register to be reported.
Returns the unmask value set by the :ENABle command.
Returns the contents of the Operation Event RegisterSets
Enable Register bits to 0.
Returns description of module in a switchbox.
Opens all channels on specified module(s)
.Returns the module type
.Returns error number/message in a switchbox error queue.
Causes a trigger to occur.
Trigger source is *TRG.
Trigger is the VXIbus ECL trigger bus line n.
Trigger source is "Trig In" (on the E1405 or E1406).
Hold off triggering.
Trigger source is the internal triggers.
Trigger is the VXIbus TTL trigger bus line n.
Query scan trigger source.
HP E1476A Switchbox Command Reference