Trouble
9-2
Screws do not flow.
Cause
・Screws in an abnormal position in the
passing plate cannot be swept away with
the brush.
・The axis of the screw thread entered the
passing plate.
・A screw has stopped in an abnormal po-
sition while moving on the rail.
・The rail does not vibrate.
(For example, a screw is obstructing the
clearance.)
- 26 -
Corrective measures
・Adjust the brush.
Adjust the passing plate.
If a proper amount of screws are loaded
into the scooping chamber the status may
be improved.
Use the optional brush. (stiffer bristles)
[Parts No: HS3-02110-2]
・Remove the abnormal screw and check
and adjust the passing plate.
・ Remove the screw in the abnormal posi-
tion. Take care not to damage the rail
groove.
Move the holding plate bracket assembly
upward to remove the screw. After, adjust
the position of the holding plate.
・Remove the screw that is obstructing the
clearance.
・ Check the vibration adjustment.
If no screw is obstructing the clearance,
consult our service section.