10. Maintenance
-
The maintenance intervals depend on the application and should be
determined by the operator carrying out temporary checks.
-
Tools required:
1 x spanner SW8
1 x spanner SW13
1 x wrench SW12
1 x wrench SW5
1 x wrench SW3
-
For the valve service we supply complete seal kits (pl. see spare
parts lists). The appropriate seal grease forms part of this scope of
supply.
-
The replacement of seals is undertaken according to the Service
Instructions.
-
The disassembly and assembly of the valve is undertaken
according to the Service Instructions.
-
All seals must be provided with a thin layer of grease before
their installation!!!
Attention!
Recommendation:
APV assembly grease for EPDM, FPM, HNBR and NBR
(0,75 kg /tin - ref.-No. 000 70-01-019/93; H147382)
(60 g /tube - ref.-No. 000 70-01-018/93; H147381)
Recommendation for screw retention
Type: Loctite 243 semi-solid
(50 ml - ref.-No. 00070-01-111/93; H206336)
Recommendation for piston seal
APV pneumatic grease:
(25 ml / tube - ref.-No. 000-70-01-008/93; H164725)
Use only food-grade grease and special grease
being suited for the respective seal material.