5. General Specifications
Max. Input Current [A]
Max. Input Current [A]
Max. Input Current [A]
Max. external pre-fuses
Soft Charge Fuses
5
(qty)
SMPS fuse
AC Fan fuse
Supply Voltage [V]
Supply Frequency [Hz]
Power Factor
Efficiency
Power loss at rated max. load (690 V)
High Overload (150%) [W]
Normal Overload (110%) [W]
Enclosure
Vibration Test [g]
Relative Humidity [%]
Ambient Temperature [de-
grees C]
Adjustable Frequency Drive
Protection
Weight
IP 00/ Chassis [kg]
IP 21/ NEMA 1 [kg]
IP 54/ NEMA 12 [kg]
1) Bussman 170M6000 series. See fuse chart.
2) Bussmann FWH-20A6F or exact equivalent, 3 per unit
3) Bussmann KTK-4 or exact equivalent, 1 per unit
4) Littlefuse KLK-15 or exact equivalent, 1 per unit
5) VLT with standard input option, no brake, no load sharing
126
VLT Type
1)
[A]
2)
AC [A]
3)
[A]
3)
[A]
5)
MG.33.U1.22 - VLT
525-690 Volt
P400
550
413
504
504
575
395
482
482
690
395
482
482
700
4
3 Phase, 525-690 ± 10%
50/ 60
>0.90 for 525 V
5818
7249
IP 00, IP 21/ NEMA 1 & IP 54/ NEMA 12
93%, +2%, -3% (IEC 68-2-3)
-10° C to 40° C [14°-104° F] continuously,
periodically at +45° C [113° F]
-25° C to +65°/70° C [-13°-149°/158° F] for
storage/ transport
Ground and short-circuit protection
221
263
263
®
is a registered Danfoss trademark.
VLT
®
Automation Drive FC 300
Instruction Manual High Power
P500
P560
574
574
607
549
549
607
549
549
607
900
900
20 (3)
4
15
0.98
7671
8715
8727
9673
0.7
236
277
272
313
272
313