11. TECHNICAL DATA
Nominal heat output kW (closed operation)
Thermal output range kW
Efficiency %
Required chimney diameter (mm)
General data
Flue gas connection: Ø mm
Possible flue gas connection Ø mm
Weight (approx.) kg
Required minimum cross-section for supply and recirculating air (with WLM) cm
Required minimum cross-section for recirculating and supply air (without WLM) cm
non-self-closing combustion chamber door (Design A)
self-closing combustion chamber door (Design A1)
Testing and values
Operation with open combustion chamber door
Level 2 BlmSchV [Ordinance in the Implementation of the Federal Immission Control Act]
15a BVG
Mass flow of flue gas g/s
Operation with open
Flue gas temperature °C
combustion chamber
Flue gas temperature behind the NSHF °C
(multiple allocation
Combustion air requirement m
not permitted)
Required supply pressure: in Pa
Mass flow of flue gas g/s
Flue gas temperature °C (on the flue gas outlet)
Operation with
Required supply pressure: in Pa
closed combustion
chamber (multiple
CO
%
2
allocation permitted)
Required diameter after M-FeuVo. cm
Combustion air requirement m
to the heating chamber wall cm
Heating chamber
distance
To the setup floor cm
Setup floor cm
Heat insulation
Mounting wall cm
(example rock wool
matting to AGI-Q
Side wall cm
132)
Stud wall with a wall that must be protected cm
Setup floor cm
Substitute insulation
material, calcium
Mounting wall cm
silicate
Side wall cm
Convection %
Heat distribution
Viewing panel %
H
O %
2
Changes and mistakes reserved
* Fulfils 15a 2015 only with AT hand piece, attention: flue gas connection + 160 mm
Varia
1Vh S
7.0
4.9-9,1
> 80
200
200
180
245
700
2
900/1090
2
3
/h
5.6
300
12
10.3
15
3
/h
19.9
13
13
10
10
10
65
35
Varia
Varia
Varia 1V
1Vh 51
1Vh 57
100h
(Export)
(Export)
17.5
17.5
10.4
12.3-21,2
12.3-21,2
7.3-13,5
>78
>78
80
200
200
250
200
200
250
180
180
200
268
268
351
700
700
700
1420/1710
1420/1710
1200/1500
-
-
-
-
-
*
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
13.1
13.4
11.4
330
333
275
12
12
12
12.2
12.1
7.9
15
15
15
44.7
45.3
40
Side: 10
7
10
10
Back: 20
0
0
0
0
0
0
0
0
13
11
12
13
13
12
10
10
10
0
0
0
0
10
9
9
10
10
9
65
62
61
35
38
39
0
0
0
0
GB 28
Varia 1V
Varia Sh
Varia
100h
SRh
(Export)
17.0
11.0
11.0
11.9-21,2
7.7-14,3
7.7-14,3
80
80
>78
250
200
200
250
200
200
200
180
180
351
300
300
700
700
700
1200/1500
1250/1500
1300/1560
1000/1200
-
-
-
*
-
-
22.1
-
-
270
-
-
-
-
-
126.1
-
-
10
15.9
9.5
10.0
319
300
330
13
11
12
9.3
10.1
9.6
15
15
15
55.7
33.1
35.6
Side: 10
12
11
Back: 20
0
0
0
0
0
0
12
11
8
12
9
8
10
10
10
0
0
0
9
9
6
9
7
6
61
57
58
39
43
42
0
0
0
*** Values were not available at the time of printing.
*** Deviating insulation guidelines apply for GET fireplace inserts.
This can be obtained from the separate GET manual.
Varia
AS-2
7.0
4.9-9,1
> 80
180
180
-
171
700
-
-
-
-
-
-
7.0
275
12
8.4
15
24.9
10
0
0
13
13
10
0
10
10
59
41
0