11. TECHNICAL DATA
Nominal heat output kW (closed operation)
Thermal output range kW
Efficiency %
Required chimney diameter (mm)
General data
Flue gas connection: Ø mm
Possible flue gas connection Ø mm
Weight (approx.) kg
Required minimum cross-section for supply and recirculating air (with WLM) cm
Required minimum cross-section for recirculating and supply air (without WLM) cm
non-self-closing combustion chamber door (Design A)
self-closing combustion chamber door (Design A1)
Testing and values
Operation with open combustion chamber door
Level 2 BlmSchV [Ordinance in the Implementation of the Federal Immission Control Act]
15a BVG
Mass flow of flue gas g/s
Operation with open
Flue gas temperature °C
combustion chamber
Flue gas temperature behind the NSHF °C
(multiple allocation
Combustion air requirement m
not permitted)
Required supply pressure: in Pa
Mass flow of flue gas g/s
Flue gas temperature °C (on the flue gas outlet)
Operation with
Required supply pressure: in Pa
closed combustion
chamber (multiple
CO
%
2
allocation permitted)
Required diameter after M-FeuVo. cm
Combustion air requirement m
to the heating chamber wall cm
Heating chamber
distance
To the setup floor cm
Setup floor cm
Heat insulation
Mounting wall cm
(example rock wool
matting to AGI-Q
Side wall cm
132)
Stud wall with a wall that must be protected cm
Setup floor cm
Substitute insulation
material, calcium
Mounting wall cm
silicate
Side wall cm
Convection %
Heat distribution
Viewing panel %
H
O %
2
Changes and mistakes reserved
Changes and mistakes reserved
* Fulfils 15a 2015 only with AT hand piece, attention: flue gas connection + 160 mm
* Fulfils 15a 2015 only with AT hand piece, attention: flue gas connection + 160 mm
Mini
7.0
4.9-9,1
>78
180
180
205
700
2
810/890
2
*
17.8
230
3
/h
86.4
12
8.8
290
14
7.9
15
3
/h
27.6
10
58
42
Mini
Speedy
Speedy
S
Sh
1V 51
1V 57
7.0
9.0
9.0
4.9-9,1
6.3-11,7
6.3-11,7
>78
80
80
180
200
200
180
200
200
-
-
180
180
205
195
200
700
700
700
810/890
1420/1710
1420/1710
-
-
*
17.8
-
-
230
-
-
-
-
-
-
85.5
-
-
12
-
-
8.8
7.2
7.5
290
342
299
14
12
12
7.9
12.2
11.7
15
15
15
27.6
21.1
23.4
9
9
10
10
0
0
0
0
0
0
0
0
9
8
16
16
9
8
16
16
10
10
10
0
0
0
0
7
6
12
12
7
6
12
12
58
64
64
42
36
36
0
0
0
0
GB 26
Speedy
Speedy
Speedy
1V 51
1V 57
1V 51
NSHF
NSHF
(Export)
10.0
10.0
14.5
7.0-13,0
7.0-13,0
10.2-18,9
> 80
> 80
> 78
200
200
200
200
200
200
180
180
180
195
200
195
700
-
700
1420/1710
1420/1710
1420/1710
1420/1710
-
-
-
-
*
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
9.3
8.8
10.9
391
392
346
(163 behind NSHF)
(170 behind NSHF)
12
12
12
9.4
10.0
12.2
15
15
15
29.8
27.7
36.8
10
10
10
0
0
0
0
0
0
16
16
16
16
16
16
10
10
10
0
0
0
12
12
12
12
12
12
64
62
64
36
38
36
0
0
0
*** Values were not available at the time of printing.
*** Values were not available at the time of printing.
*** Deviating insulation guidelines apply for GET fireplace inserts.
*** Deviating insulation guidelines apply for GET fireplace inserts.
This can be obtained from the separate GET manual.
This can be obtained from the separate GET manual.
Speedy
1V 57
(Export)
14.5
10.2-18,9
>78
200
200
180
200
700
-
*
-
-
-
-
10.2
327
12
13.2
15
34.0
10
0
0
16
16
10
0
12
12
62
38