Summary of Contents for Spartherm ZERO CLEARANCE FIREPLACE
Page 1
Installation and Operating Instructions The Spartherm Zero Clearance fireplaces ha ve been tested and certified b y CSA based on ZERO CLEARANCE FIREPLACE the following standards: UL 127 / ULC S610. EPA : U.S.ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 emissionstandards using crib wood.
Page 2
WARRANTY. installation room, e.g. by means of an exhaust fan organic fire starters. Never start a fire with gasoline, SPARTHERM ZERO CLEARANCE FIREPLACES-800 PLEASE REFER TO WARRANTY CONDITIONS IN THE or similar mechanical blower, as this could affect kerosene, or charcoal starter.
TABLE OF CONTENTS 1. Installation overview 6. Maintenance 6.1 Ash removal procedures 2. Introduction 6.2 Creosote formation and removal 2.1 Example of identification plate 6.3 Runaway or chimney fire 2.2 Dimensions 6.4 Chimney cleaning 2.3 Specification 6.5 Glass replacement 2.4 General instructions 6.6 Care of glass 2.5 General Information 6.7 Cleaning the glass ceramic sheet...
1. INSTALLATION OVERVIEW SPECIFICATIONS ZERO CLEARANCE FIREPLACE-800 Spartherm Zero Clearance Fireplace Zero Clearance Fireplace-800 Weight of fireplace 364 lbs Fireplace exterior: Width/height/ W 33 3/16" X H 26 1/8" X D 19 3/4" depth (inches) Recommended amount of wood when 2.5 kg/hr...
As with all plastic bags, these are not toys and The Spartherm zero clearance fireplaces have been away to avoid burns or clothing ignition. should be kept away from children and infants.
2.3 SPECIFICATION moisture in the steel and refractory bricks. The ini- Expansion / contraction noises during heating up and tial heat output will be reduced while the moisture cooling down cycles are normal and to be expected. Conversion Factors is being drawn from the appliance and it will be Fire chamber Minimum Power Maximum power...
2.6 AIR SYSTEM 2.6.1 CONNECTION DIRECTLY TO THE UNIT The ZC Fireplaces-800 do require a combustion air outside connection. To connect the separate combustion air directly to the unit you need to have the right separate combustion air connector Ø 5". Fix the connector directly to the unit. 800Z/C - backside air intake backside air take Grills...
3. INSTALLATION PLANNING CLOSURE VALVE PLEASE NOTE: 3.1 MINIMUM CLEARANCES TO 1 5/8“ SPACER AT THE BACK COMBUSTION AIR INTAKE REQUIREMENTS. COMBUSTIBLES It is mandatory to install a closure valve to prevent It is recommended that the 5" Combustion air intake WARNING condensate formation and to prevent the room from DO NOT PLACE ANY COMBUSTIBLE MATERIALS (FUR-...
3.1.1 PLACEMENT FROM COMBUSTIBLE MATERIALS PLEASE NOTE- 1/2" SPACERS ON THE SIDES AND 1 The recommend minimum distance from stove to fur- 5/8" AT THE BACK. niture is 48 inches. Note that some furniture is more 1 5/8“ SPACER AT THE BACK PLEASE KEEP THE SPACES CLEAR OF INSTALLATION easily affected by heat and may need to be moved to PLEASE NOTE- 1/2"...
800 Z/C FIREPLACE 3.2 FLANGES AND ANCHOR PLATE 33 3/16" / 843 mm NOTE! The anchor plate is not included with the unit. 1/2" / 13 mm Use only an chimney certified as UL 103HT or ULC S-629. The dimensions and positioning of the differ- 1 5/8"...
4. INSTALLATION 4.1.1 ZC FIREPLACE-800 4.1 HEARTH EXTENSION WARNING Install the hearth extension only as illustrated! A 16" / 406 mm (USA) and 18" / 457mm (Canada) minimum hearth extension in front of the stove made of non com- bustible material is required.In front of the unit, the hearth extension must extend 6" on each side, 8" in Canada The non combustible material that is used must be UL 1618 ember protection or in Canada CSA-B365.
Page 13
The hearth requirements are summed up in the following table: Mantle clearance 25" to a 8" deep mantle. 25" FOR 8" MANTLE Floor protection requirements zero clearance fireplace 800 Distance from floor to the 15" USA/CANADA bottom of the door glass Hearth extension in front of 18"...
4.3 CHIMNEY INSTALLATION 4.3.2 CHIMNEY INSTALLATION NOTES recommended locaction marginal locaction This fireplace is designed and approved for installation No other device must be added to the chimney con- marginal locaction with the following brands of chimneys measuring 6" and nected to the fireplace.
4.3.3 CHIMNEY INSTALLATION 4. Every time the chimney passes through a ceiling or a wall, install the appropriate firestop. When you reach INSTRUCTIONS the desired height, install the roof support. (Refer to instructions included with the support. 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass and install radiation 5.
PLEASE USE THE GLOVE THAT IS SUPPLIED WHEN FIRE UNATTENDED WHEN THE DOOR IS UNLATCHED oxygen is getting into the combustion chamber. The The Spartherm 800 Z/C Fireplace has a pre set com- OPERATING THE INSERT! AS UNSTABLE WOOD COULD FALL OUT OF THE FIRE flames, however, are more efficient.
Page 18
DOOR ASSEMBLY - SPARE PARTS. WARNING WARNING ROBAX 4MM CERAMIC GLASS. USE ONLY AS PER MANUFACTURERS STANDARD AND SPARE PARTS. HOT GLASS – WILL CAUSE BURNS. The combustion-air damper should NOT be altered for increased firing for any reason! DO NOT TOUCH GLASS UNTIL COOLED WARNING NEVER!!! ALLOW CHILDREN TO TOUCH THE GLASS.
5.1 FIRE EXTINGUISHERS / SMOKE fireboxes backside height and burn at a medium low Cut the wood so that it will fit horizontally, front to 5.3 LIGHTING A FIRE setting. The whiteness of the bricks and the cleanli- back, making for easier loading and less of a likeli- DETECTORS Lighting the fire in your fireplace is very easy if you fol- ness of the glass are good indicators of your operating...
5.3.1 FLASH FIRE 5.3.3 SMOKING 6.3 RUNAWAY OR CHIMNEY FIRE WARNING A flash fire is a small fire burned quickly when A properly installed appliance should not smoke. If WARNING you don’t need much heat. After your kindling has yours does, check the following: IMPROPER DISPOSAL OF ASHES RESULTS IN FIRES.
• Proper tools should be used, including a brush appliance thoroughly hot, using green or wet wood, All Spartherm inserts are supplied with Robax glass specifically designed for chimney cleaning. closing the draft so far that there is insufficient air for in the door.
Appliance emits • Paint curing. See “GENERAL INSTRUCTIONS” odour. section. Stove doesn’t • Wood is too wet. Spartherm Feuerungstechnik GmbH gives a 5-year burn hot • Insufficient draft? Add more pipe. warranty on: enough. • Also ensure that the air opening is not obstructed.
Your specialist dealer/contractor will gladly advise If such proof is not produced Spartherm Feuerung- and assist you in matters not covered by our warranty stechnik GmbH shall not be obliged to honour the terms and conditions and undertakings.
10. SERVICE HISTORY Appliance Service History This heater must be serviced annually depending on usage. Date Dealer Name Service Technician Name Service Performed Special Concerns...
Page 28
SPARTHERM THE GLOBAL BRAND FOR YOUR LIVING ROOM Your specialist dealer Spartherm Feuerungstechnik GmbH · Maschweg 38 · 49324 Melle Phone +49 5422 94 41-0 · www.spartherm.com...
Need help?
Do you have a question about the ZERO CLEARANCE FIREPLACE and is the answer not in the manual?
Questions and answers