Spartherm Zero Clearance Fireplace-600 Installation And Operating Instructions Manual

Spartherm Zero Clearance Fireplace-600 Installation And Operating Instructions Manual

Advertisement

Installation and Operating Instructions
ZERO CLEARANCE FIREPLACE
ZERO CLEARANCE FIREPLACE-600
ZERO CLEARANCE FIREPLACE-700
Save this manual and keep it in a safe place that it is easy to refer to it.
The Spartherm Zero Clearnace fireplaces have been tested and certified by CSA based on thefollowing standards:
UL 127 / ULC S610. EPA : U.S.ENVIRONMENTAL PROTECTION
AGENCY Certified to comply with 2020 emissionstandards using cord wood.
1
Spartherm Feuerungstechnik GmbH
Maschweg 38 · 49324 Melle
Phone +49 5422 9441-0
Fax +49 5422 9441-14
www.spartherm.com

Advertisement

Table of Contents
loading

Summary of Contents for Spartherm Zero Clearance Fireplace-600

  • Page 1 Installation and Operating Instructions ZERO CLEARANCE FIREPLACE The Spartherm Zero Clearnace fireplaces have been tested and certified by CSA based on thefollowing standards: UL 127 / ULC S610. EPA : U.S.ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 emissionstandards using cord wood.
  • Page 2: Introduction And Unit Description

    IINTRODUCTION AND UNIT DESCRIPTION 1.14 g/hr burning appliances from an adequate air supply. Keep combustible items, like curtains, furniture, news- SPARTHERM ZERO CLEARANCE FIREPLACES-600/700 WARRANTY. • Make sure not to create negative pressure in the papers, and books, away from your appliance.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION AND UNIT DESCRIPTION DISTANCE TO COMBUSTIBLE MANTLE CHIMNEY CLEANING U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 particulate emission stan- SAFETY INFORMATION · CHIMNEY INSTALLATIONS GLASS REPLACEMENT dards using cordwood 600 module 1.67 g/hr and 700 module 1.14 g/hr, Method 28R SAFE WOOD-BURNING PRACTICES LISTED CHIMNEYS...
  • Page 4: Installation Overview

    SPECIFICATIONS ZERO CLEARANCE FIREPLACE-600/ 1. INSTALLATION OVERVIEW ZERO CLEARANCE FIREPLACE-700 : Spartherm Zero Clearance Fireplace Zero Clearance Firepla- Zero Clearance Fireplace-700 ce-600 Weight of fireplace 265 lbs (120kg) 298 lbs (135kg) Fireplace exterior: Width/depth/ 25 5/16“ / 19“ / 23 5/16“...
  • Page 5 The Spartherm zero clearance fireplaces have been away to avoid burns or clothing ignition. As with all plastic bags, these are not toys and tested and certified by CSA based on the following •...
  • Page 6: Examples Of Identification Plates

    Particulate emission standards using cord wood Particulate emission standards using cord wood Particulate emission standards using cord wood Model: Spartherm Cassette 600 Zero Clearance Model: Spartherm Cassette 600 Zero Clearance Model: Spartherm Cassette 700 Zero Clearance Model: Spartherm Cassette 700 Zero Clearance...
  • Page 7 Nennmaß: >120−400 >400−1000 <=6 >6−30 >30−120 >1000−2000 >2000−4000 Abmaße [mm auf 100 mm]: 0,15 Abmaße: Allgemeintoleranzen nach DIN 7168 mittel Nennmaß des kürzeren Schenkels: >10−50 >50−120 >120−400 >400 <=10 Abmaße [Winkelminuten]: Abmaße [mm auf 100 mm]: 0,15 Allgemeintoleranzen nach DIN 7168 mittel 2.2 DIMENSIONS back cumbustion air connector back cumbustion air connector...
  • Page 8: General Instructions

    2.3 SPECIFICATION moisture in the steel and refractory bricks. The ini- Expansion / contraction noises during heating up and tial heat output will be reduced while the moisture cooling down cycles are normal and to be expected. Fire chamber Minimum Power Maximum power Efficiency* Chimney type...
  • Page 9: Air System

    2.6 AIR SYSTEM 2.6.1 CONNECTION DIRECTLY TO THE UNIT The ZC Fireplaces-600/700 do require a combustion air outside connection. To connect the separate combustion air directly to the unit you need to have the right separate combustion air connector Ø 5”. Fix the connector directly to the unit. 600 and 700 - backside air intake backside air take Grills...
  • Page 10: Installation Planning

    CLOSURE VALVE 3. INSTALLATION PLANNING 3.1 MINIMUM CLEARANCES TO PLEASE NOTE: COMBUSTION AIR INTAKE REQUIREMENTS. COMBUSTIBLES It is recommended that the 5” Combustion air intake WARNING It is mandatory to install a closure valve to prevent duct is installed in a correct manner. DO NOT PLACE ANY COMBUSTIBLE MATERIALS (FUR- condensate formation and to prevent the room from P l e a s e...
  • Page 11 Für die Herstellung und den Entwurf wird das Eigentum ausdrücklich vorbehalten und der gesetzliche Schutz gemäß BGB §§ 823 ,826, 1004 voll in Anspruch genommen. Unbefugte Vervielfältigungen, Verbreitungen und Wiedergaben - ganz oder teilweise - werden gemäß §§ 2 Absatz Ziffer 7, 96 ff. und 106 ff. Urhebergesetz sowie u.U. nach 1, 3, 4, 18 und 19 UWG zivil- und strafrechtlich verfolgt. Bezüglich Rechtsansprüche u.
  • Page 12: Flanges And Anchor Plate

    3.1.2 PLACEMENT FROM COMBUSTIBLE MATERIALS 3.2 FLANGES AND ANCHOR PLATE ZC FIREPLACE-600 NOTE! The anchor plate is not included with the unit. Use only an chimney certified as UL 103HT or ULC 25 9/16” / 649mm S-629. The dimensions and positioning of the different air inlet and outlet are available in the table in 1/2”...
  • Page 13 ZC FIREPLACE-700 29 5/8”/ 752mm 1/2” / 13mm 1 5/8” / 41mm 9 1/4” or 4 1/2” with R value 2,957 in Canada or 6 1/2” with R value 2,957 in USA...
  • Page 14 4. INSTALLATION 4.1.1 ZC FIREPLACE-600 4.1 HEARTH EXTENSION WARNING Install the hearth extension only as illustrated! A 16” / 406mm (USA) and 18” / 457mm (Canada) minimum hearth extension in front of the stove made of non com- bustible material is required.In front of the unit, the hearth extension must extend 6’’ on each side, 8” in Canada The non combustible material that is used must be UL 1618 ember protection or in Canada CSA-B365.
  • Page 15: Distance To Combustible Mantle

    4.2 DISTANCE COMBUSTIBLE MANTLE The hearth requirements are summed up in the following table: MANTLE MINIMUM CLEARANCES Floor protection reqiurements zero clearance fireplace 600 zero clearance fireplace 700 Distance from top of glass to mantle 21” = or 4 1/2” -with R value 2,957 (Canada) / 6 1/2” - with R vlaue 2,957 (USA 9 1/4”or4 1/2”...
  • Page 16: Chimney Installations

    4.3 CHIMNEY INSTALLATION • All chimney installations must include at least one support. Reducing the amount of chimney weight This fireplace is designed and approved for installation on the fireplace will help avoid the noise created with the following when the fireplace expands. This can be achieved brands of chimneys measuring 6”...
  • Page 17: Chimney Installation Instructions

    The table below shows the minimum height requirements, fireplace included, according to the number of elbows: 2. From below, install a firestop supplied by the chimney manufacturer in each ceiling/floor separation through which the chimney will pass. At the attic level, install an attic radiation shield from above. chimney number of elbows minimum height...
  • Page 18: Examples Of Typical Installations

    4.3.4 EX AMPLES OF TYPICAL INSTALLATIONS rain cap storm collar rain cap flashing storm collar attic attic radiation shield flashing attic attic radiation shield elbow 1st floor chimney section radiation shield 1st floor radiant shield chimney section wall radiation shield fireplace elbow basement...
  • Page 20: Operation

    GLOVES TO PREVENT INJURY. DO NOT LEAVE THE PLEASE USE THE GLOVE THAT IS SUPPLIED WHEN into the combustion chamber. The flames, however, are Spartherm Inserts are equipped with an air con- FIRE UNATTENDED WHEN THE DOOR IS UNLATCHED OPERATING THE INSERT! more efficient.
  • Page 21 Caution: A - Air supply open: DOOR ASSEMBLY - SPARE PARTS. Never close the air lever of the air control com- (when lighting the fire or pletely or before the fire has started to burn adding new wood). The ROBAX 4MM CERAMIC GLASS. efficiently as it will create smoke and the fire would be control lever is pushed USE ONLY AS PER MANUFACTURERS STANDARD AND SPARE PARTS.
  • Page 22: Fire Extinguishers/Smoke Detectors

    6.1 FIRE EXTINGUISHERS / SMOKE 6.3 LIGHTING A FIRE backside of the firebox or, if not present, to 50% of the Firewood should be split, stacked in a manner that air DETECTORS fireboxes backside height and burn at a medium low can get to all parts of it and covered in early spring to setting.
  • Page 23: Flash Fire

    6.3.1 FLASH FIRE 6.3.3 SMOKING affect the extraction of flue gases from the wood the wood pyre to help start the fire. (paper is not rec- insert. Check the combustion air supply (if required, ommended because it burns too quickly and causes open the cover flap)! ash to circulate).
  • Page 24: Ash Removal Procedures

    7.1 ASH REMOVAL PROCEDURES .5 GLASS REPLACEMENT the heating season to determine if a creosote buildup information on how to handle a chimney fire. has occurred. If creosote has accumulated it should be • After the chimney fire is out, clean and inspect removed to reduce the risk of a chimney fire.
  • Page 25: Cleaning The Glass Ceramic Sheet

    WARNING Model & Serial Number of appliance Installation date of appliance Part number All Spartherm inserts are supplied with Robax glass Description of part in the door. Finish Robax is a ceramic glass. Do not use substitute glass and order replacement IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED.
  • Page 26: Exploded View

    • Not enough air? Ensure air control is fully open. Also ensure that the air opening is not obstructed. Spartherm Feuerungstechnik GmbH gives a 5-year Wood burns • Air control may need to be adjusted down. warranty on: too fast.
  • Page 27: Warranty Exclusions

    We particu- If such proof is not produced Spartherm Feuerung- larly advise you to have your wood insert/ stechnik GmbH shall not be obliged to honour the stove serviced regularly by a stove fitter.
  • Page 28: For Your Information

    10.6 FOR YOUR INFORMATION...
  • Page 29: Service History

    11. SERVICE HISTORY Appliance Service History This heater must be serviced annually depending on usage. Date Dealer Name Service Technician Name Service Performed Special Concerns...
  • Page 30 SPARTHERM THE GLOBAL BRAND FOR YOUR LIVING ROOM Your specialist dealer Spartherm Feuerungstechnik GmbH · Maschweg 38 · 49324 Melle Phone +49 5422 9441-0 · Fax +49 5422 9441-14 · www.spartherm.com...

This manual is also suitable for:

Zero clearance fireplace-700700-zc600-zc

Table of Contents