11. TECHNICAL DATA
Nominal heat output kW (closed operation)
Thermal output range kW
Efficiency %
Required chimney diameter (mm)
General data
Flue gas connection: Ø mm
Possible flue gas connection Ø mm
Weight (approx.) kg
Required minimum cross-section for supply and recirculating air (with WLM) cm
Required minimum cross-section for recirculating and supply air (without WLM) cm
non-self-closing combustion chamber door (Design A)
self-closing combustion chamber door (Design A1)
Testing and values
Operation with open combustion chamber door
Level 2 BlmSchV [Ordinance in the Implementation of the Federal Immission Control Act]
15a BVG
Mass flow of flue gas g/s
Operation with open
Flue gas temperature °C
combustion chamber
Flue gas temperature behind the NSHF °C
(multiple allocation
Combustion air requirement m
not permitted)
Required supply pressure: in Pa
Mass flow of flue gas g/s
Flue gas temperature °C (on the flue gas outlet)
Operation with
Required supply pressure: in Pa
closed combustion
chamber (multiple
CO
%
2
allocation permitted)
Required diameter after M-FeuVo. cm
Combustion air requirement m
to the heating chamber wall cm
Heating chamber
distance
To the setup floor cm
Setup floor cm
Heat insulation
Mounting wall cm
(example rock wool
matting to AGI-Q
Side wall cm
132)
Stud wall with a wall that must be protected cm
Setup floor cm
Substitute insulation
material, calcium
Mounting wall cm
silicate
Side wall cm
Convection %
Heat distribution
Viewing panel %
H
O %
2
Changes and mistakes reserved
* Fulfils 15a 2015 only with AT hand piece, attention: flue gas connection + 160 mm
Varia
2Lh / 2Rh
11.0
7.7-14,3
80
200
200
180
270
700
2
1250/1500
2
21.2
270
3
/h
176.1
14
9.6
330
12
10.0
15
3
/h
36.5
12
10
53
47
Varia
Varia
Varia AS
2Lh / 2Rh
2Lh / 2Rh
2Lh/2Rh
NSHF
7.0
12.0
7.0
4.9-9,1
8.4-15,6
4.9-9,1
> 78
80
80
200
200
200
200
200
200
180
180
180
270
270
212
700
-
700
750/900
1280/1540
1200/1400
-
-
-
-
*
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
7.7
10.0
6.6
350
245
311
(218 behind NSHF)
12
12
12
8.3
10.0
11.2
15
15
15
33.5
36.5
19
8
13
10
0
0
0
0
0
0
0
0
7
13
7
11
7
11
7
11
10
10
10
0
0
0
0
6
10
6
9
6
9
6
9
51
53
58
49
47
42
0
0
0
0
GB 34
Varia AS
Varia
Varia
2Lh/2Rh
2LR-80h
2LR-80h
(Export)
(Export)
11.0
10.4
16.0
7.7-14,3
7.2-13,5
11.2-20,8
80
> 80
> 80
200
200
200
200
200
200
180
180
180
181
275
275
700
700
700
1200/1400
1200/1400
1200/1400
1140/1350
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8.7
9.5
12.9
349
283
305
12
12
12
9.7
10.1
10.9
15
15
15
34.5
31.3
44.7
10
10
10
0
0
0
0
0
0
11
16
16
11
16
16
10
10
10
0
0
0
9
12
12
9
12
12
58
53
53
42
47
47
0
0
0
*** Values were not available at the time of printing.
*** Deviating insulation guidelines apply for GET fireplace inserts.
This can be obtained from the separate GET manual.
Varia
2L / 2R
100h
11.0
7.7-14,3
>78
250
250
200
280
700
*
20.2
210
-
207.5
10
12.0
280
12
8.2
15
41.1
10
0
5
10
10
10
4
8
8
49
51
0

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mini R1V51 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Mini r1v 57Mini r1v 51 nshfMini r1vh 57Mini r1vh 57 nshfMini z1Mini r1v 57 nshf ... Show all

Table of Contents