Technical specifications

Battery box

Delta model name
Delta part number
Rated capacity
Maximum capacity
Usable capacity (80% discharge)
Maximum number of charging cycles (80% discharge)
Voltage range
Nominal charging power
Nominal discharge power
Maximum charging current
Maximum discharge current
Battery technology
Dimensions
Weight
Protection degree
Optimal operating temperature range
Maximum temperature range:
Charging
Discharging
Relative humidity
Certificates
56
BX 6 .0 battery box
Hybrid BX 6.0
RPB602201120
6 kWh
6.4 kWh
4.8 kWh
6000
85 ... 104 V
2.5 kW
3 kW
30 A
35 A
Lithium ions
553 x 596 x 200 mm
75 kg
IP55
+10 ... +30 °C
0 ... +45 °C
-10 ... +45 °C
0 ... 90%, non-condensing
UN38.3