Delta Hybrid E5 Installation Instructions Manual page 7

Battery storage system
Hide thumbs Also See for Hybrid E5:
Table of Contents

Advertisement

In this example, the
inverter is connected to the
L1 phase.
E5 Inverter
The Smart Monitor assists with
setup and monitoring of the system
and is connected to the inverter via
RS485.
1
If the Smart Monitor is connected to
a router, the system can be
monitored from a PC.
The plug connector for the washing machine is
Washing machine
connected directly to L1. If mains power is
present, current is supplied to the plug connec-
tor. In the event of mains failure, the plug
Installation Instructions for the Hybrid E5 Battery Storage System EU V1 EN 2018-09-17
System overview
Hybrid E5 Battery Storage System
for use with three-phase mains
L3 PE
L1 L2
N
Smart Monitor
Router
Battery box 1
Battery box 2
(optional)
L1
The current clamps measure
current and voltage in each phase.
1 Current clamp
Per phase
Current
household meter
meter
The current meter records the
measured data supplied by the
current clamps and sends the
data to the inverter.
In normal operation, the batteries are charged via the
solar modules. Power is only ever supplied to the
batteries via the mains to perform a maintenance
charge, if necessary.
Upon interruption of the mains supply, the Hybrid E5
System switches to battery supply power, thereby
preventing critical electrical equipment from shutting
System overview
Electronic
House connection box
To mains
7