The following images show the wiring for con-
nection variant 1. The wiring must be adjusted
accordingly for the other connection variants.
12 mm
12 mm
Installation Instructions for the Hybrid E5 Battery Storage System EU V1 EN 2018-09-17
52.5 mm
55 mm (PE)
Connecting the inverter to the mains (AC)
Readying AC cable for use and connecting it
1. Remove the insulation from the cable and wires.
Do not twist the wire ends because this reduces the
contact surface area with the wire end sleeves.
2. Fit and crimp the wire end sleeves to the ends of the
wires.
3. Unscrew the nut and housing from the AC plug.
4. Insert the wires of the AC cable into the correct pin
inserts and tighten with a screwdriver.
The first image shows the wiring for use of the
Hybrid E5 system in isolated operation; the second
image shows the wiring for use without isolated
operation.