3
Mounting and installation
3/2-way valve
Ident. code W
Ident. code X
Tab. 3.3 Connections to valves with ident. code X and W
Valve with ident. code I, 2x 2/2-way valves:
– With this valve, vacuum is supplied at port (5). Solenoid coil 14 switches the vacuum
to port (4).
– The operating pressure at port (1) can be used as an ejector pulse at port (2).
The operating pressure is switched to port (2) with solenoid coil 12.
– If the valve terminal is also equipped with other valves, operate this valve in
a separate pressure zone with separate exhaust duct (5).
3.4.4

Connecting the pneumatic lines

Note
Do not use fittings with taper thread. The thread in the manifold sub-base, supply and
end plates can be damaged through taper thread!
• Use blanking plugs to seal ports not required for the functional reliability of the valve terminal.
• Mount the fitting or the silencer (è Tab. 3.4). Then lay the tubing lines.
In the valve terminal, the pilot exhaust air on the right end plate must be exhausted
through port (82/84).
30
Compressed air or vacuum
via port
(2)
(4)
Exhaust air via port
(5)
(3)
Festo – MPAC-VI-EN – 2017-12a – English