SECTION 2
Installation and Connections

Power Supply and Ground

Wire the power supply and the ground to the top terminal block, and tighten the screws to a torque of
N·m.
0.49
After wiring, check to make sure that the wiring is correct.

Crimp Terminals and Cables

The terminal block uses M3 terminal screws.
Use appropriate crimp terminals for M3 screws, as shown below.
Recommended Model
Forked
6.2 mm max.
Round
6.2 mm max.

Ground Wiring

Be sure to wire the protective conductor of the equipment independently. To avoid damage to the
equipment, do not share the protective conductor wiring with any other devices nor wire the pro-
tective conductor terminal to the girder.
Keep the ground line as short as possible.
V530-R160
44
Operation Manual
Manufacturer
Model
J.S.T. Mfg Co., Ltd.
V1.25-N3A
J.S.T. Mfg Co., Ltd.
V1.25-MS3
Ground to 100 Ω or less
Recommended wire size
1.31 to 1.65 mm