 Continuous Reading (When Trigger Mode is [Continuous Reading])
Enter RUN mode.
OFF
RUN
ON
OFF
TRIG B
ON
OFF
BUSY
ON
OK/NG
OFF
GATE
ON
(RS-232C)
Note: The output time to RS-232C changes depending on the data volume and
Output signal
Output signal
RUN
Turns ON during RUN mode.
BUSY
Shows that the V530-R160 is reading an image, changing settings, etc. Do not input the
next command while the BUSY signal is ON. Otherwise, the commands input during com-
mand execution or processing may not be properly executed.
OK/NG
Outputs the judgement under the set reading conditions. (Can be set to turn ON for either
OK or NG judgement.)
GATE
Used to control the timing with which the reading judgement is read at the host device.
The duration for which the GATE terminal is turned ON can be set as required for the host
device to correctly read the reading judgement.
Make the output cycle longer than the gate ON delay plus the gate ON time, but shorter
than the duration of the reading (TRIG A input). If the cycle is longer than the duration of
the reading, the input timing falls behind as readings are repeated. Gate ON delay, Gate
ON time and Output period are set under the set communications conditions.
Refer to page 192.
Input signal
Signal
TRIG B
Performs continuous reading while the TRIG B terminal is ON.
Note: A delay of 33.3 ms max. occurs before starting to read images
after the TRIG B signal is turned ON.
Perform reading.
Perform reading.
Judgement
Gate ON delay
Gate ON time
Output period
baud rate.
Communication with the Host
Leave RUN mode.
Perform reading.
Function