 Auto Pattern Select
If multiple patterns are registered, the controller references the patterns in sequence starting
from pattern 0, and checks them by comparison against the read code.
If ON is set for this function, the controller first references the pattern used immediately before,
then references the rest in order of diminishing frequency of use.
Auto pattern
select: OFF
Pattern 0
Referenced in the order Pattern 0
Auto pattern
select: ON
Pattern 0
Pattern frequency
2 times
of use
The order of priority of the patterns can be confirmed on the Pattern list screen.
Refer to pages 106 and 135.
When the first reading starts (when the pattern frequency of use is 0), the controller starts referenc-
ing from pattern 0.
When a registered pattern is deleted, the frequency of use of the relevant pattern is cleared.
Note also that if the controller power is switched OFF without saving the setting data, the pattern fre-
quency of use information is cleared. If the setting data has been saved, the frequency of use infor-
mation is retained.
Pattern 1
Pattern 2
(Priority 01) (Priority 02) (Priority 03)
Pattern 1
Pattern 2
10 times
5 times
Referenced in the order Pattern 3
(Priority 01) (Priority 02)
Setting Reading Conditions
Pattern 3
Pattern 4
Pattern 1
Pattern 2...
Pattern 3
Pattern 4
0 times
Pattern used
immediately before
for reading
Pattern 1
Pattern 2
(Priority 03)
SECTION 5
Pattern 0...
(Priority 04)
V530-R160
113
Operation Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

V530-r160ep

Table of Contents