Omron V530-R160E User Manual page 239

2d code reader
Hide thumbs Also See for V530-R160E:
Table of Contents

Advertisement

The screen for setting the communications specifi-
cations will be displayed.
5.
Make the settings for each item.
6.
Select End.
The setting will be registered and the screen in
Set Items and their details
Item
Interface
Baud rate (See note 1.)
Data length
Parity bits
Stop bits
Header
Footer
FCS
Mode
Protocol (See note 2.)
The asterisk (*) indicates the default setting.
Note 1: Since communications speeds higher than 20 kbps are not defined with the RS-232C standard,
depending on the cable length, if 38400 bps or a higher setting is selected it may not be possible to
perform communications properly.
If this happens, change the setting to 19200 bps or lower.
Note 2: The XMODEM (-1K) protocol is not supported.
4.
will return.
RS-232C*, RS-422
2400, 4800, 9600, 19200, 38400*,
57600,115200 (bps)
7, 8* (bit)
None*, Odd, Even
1*, 2 (bit)
None*, STX, ESC
CR*, LF, CR+LF, ETX
OFF*, ON
Select Host Link. (Normal*, Host link)
XMODEM*, ZMODEM
SECTION 8
Communication with the Host
Selection
The same settings as those of the
Programmable Controller
Operation Manual
V530-R160
237