System Time; System Day; Test Transmission Time; Test Transmission Day - DSC Skyroute CL3050 Installation & Programming Manual

Standalone wireless communicator compatible with all powerseries keypads
Table of Contents

Advertisement

[15] System Time

When the time and day have been programmed, the values are saved and are
used as the current time and day whenever the Skyroute CL3050 does a power
up. Time and day programming is only required if the installer desires the Sky-
route CL3050 to test transmit at a specific time and/or day. There is no "loss of
time" trouble on the Skyroute CL3050.
Default - 0000 - 2359
Note
[16] System Day of the Week
See section [15].
Option 1. Default - ON
Option 2 - 8. Default - OFF

[17] Test Transmission Time

When the Skyroute CL3050 is powered up for the first time, or after a default
reset; it will check if the test transmission time and day are programmed. If they
are not, a random time (0000 - 2359) will be programmed into this location. The
Skyroute CL3050 will randomly generate this value.
Note:

[18] Test Transmission Day

When the Skyroute CL3050 is powered up for the first time, or after a default, it
will check if the test transmission time and day are programmed. If they are not,
a random day (Sunday-Saturday) will be programmed into this location. The Sky-
route CL3050 will randomly generate this value. Because one test transmission
weekly is the most common configuration, this will allow the installer to setup
the Skyroute CL3050 without keypad programming.
Option 1-8. Default - [Random] - One only will be enabled.

[20] Transmission Options

When the following options are enabled the reporting codes listed in Appendix A
are sent to Connect 24.
Options 1, 2 - Zone Alarm/Zone Alarm Restores
When a zone is violated or restored, the reporting codes listed in Appendix A will
be sent.
Note:
Note:
Option 1. Default - ON, Option 2. Default - OFF
If AC Power is detected, it will be used to provide the time base for the
internal clock. If AC power is not detected the internal clock will auto-
matically use the crystal time base.
Due to traffic volume, when selecting test transmission times, select a
time that is not on the :30 minute mark (e.g., 02:24, 04:07).
If generic reporting is enabled and multiple alarms occur during the
delay programmed in Section [23], only one alarm reporting code will
be sent.
Zone alarm restorals enabled with generic zone reporting enabled can
cause unpaired events to be sent to Connect 24.
6 Programming Descriptions
13
All Modes
All Modes
All Modes
All Modes
All Modes
Modes 2, 3