Enroll Button; Terminal Connections - DSC Skyroute CL3050 Installation & Programming Manual

Standalone wireless communicator compatible with all powerseries keypads
Table of Contents

Advertisement

Skyroute CL3050 Standalone Wireless Communicator
Note: Multiple trouble conditions are displayed (flashed) in sequence.
Red LED
The red LED will flash to provide event transmission status for the following
events:
Green LED
The green LED will light continuously if the (RSSI) signal is acceptable. If signal
strength is not acceptable the LED will turn OFF. Detailed information on signal
strength can be accessed by momentarily pressing and releasing the enroll
button. The green, yellow and red LEDs will light to indicate the range of signal
strength. Refer to Section 2 Step 3.
3.2 Enroll Button (see figure 2)
The Skyroute CL3050 Enroll button is located on the outside of the plastic hous-
ing directly below the status LEDs. The enroll button performs three functions.
Pressing this button during the first 15 seconds of power up will toggle
between Mode 1 and Mode 2 to enable mode selection.
Pressing and releasing this button momentarily at any time after the power
up sequence will display the detailed RSSI status indicated above.
Holding this button down for a period of 2 seconds continuously will cause
the Skyroute CL3050 to send a test transmission to Connect 24, this long
debounce will be indicated to the user by the red LED flashing once.
3.3 Terminal Connections (see figure 2)
RED
BLK
YEL
GRN
COM
1 Flash
1 Flash
2 Flashes
9-12V
Positive Input or 9-12V
DC
Note: 12V
is required for programming or for operation with a
DC
PC5108 zone expander. Mode 1 and Mode 2 may be operated
with an AC Supply.
9-12V
Ground or 9-12V
DC
Mode 1 - The YEL terminal functions as the Bell input.
Mode 2 - This terminal functions as the zone 1 input.
Mode 3 - This terminal connects to the YEL Keybus terminal when
using a PC5108 zone expander or PowerSeries keypad.
Mode 1 - The GRN terminal functions as the TLM Trouble input.
Mode 2 - This terminal functions as the zone 2 input.
Mode 3 - This terminal connects to the GRN Keybus terminal when
using a PC5108 zone expander or PowerSeries keypad.
Mode 1 - This terminal functions as the common terminal for the Bell
Input on the YEL terminal, the TLM trouble input on the GRN terminal
and the Trouble Output on the PGM terminal.
Mode 2 - This terminal functions as the common terminal for zone 1
(YEL) and zone 2 (GRN).
Mode 3 - This terminal functions as the common terminal for the
Trouble Output
Enroll button held down for 2 seconds
Event transmitted to cellular network
Event acknowledged by Connect 24.