5
Mount Unit
Remove the front cover if required
Disconnect flying leads from battery and power leads from the RED and BLK
terminals (if connected).
Remove two screws securing battery clamp. Remove battery
Mount backplate of unit to wall or over electrical junction box using the
four screws provided.
Note:
Route wiring through the access holes provided and connect to terminal
strip.
power up unit by connecting battery and power source.
6
Enroll Unit
Call Connect 24 and Enroll the Skyroute CL3050. Refer to page (ii) for contact
information and a list of information required to complete the enrollment with
the Connect 24 Voice Response Unit.

Testing

2.2
Program Mode: If you have wired the unit to power up in the programming
mode. Follow the steps outlined in Section 6, Programming Descriptions and
record the program settings in Section 7, Programming Worksheets.
Test Transmission - Pressing and holding the enroll button for 2 seconds will
send a test transmission to the central station via Connect 24. Refer to Enrol
Button in Section 3, Controls and indicators for test transmission details.
Mode 1: Disable the telephone line connected to the control panel. Simulate
Burglar and Fire Zone violation. Verify that the Skyroute CL3050 transmits the
events to the central station.
Mode 2 & 3: Simulate Faults, Tampers, and Zone violations in accordance with
the settings outlined in Sections 6, Programming Descriptions. Verify that the
Skyroute CL3050 transmits the events to the central station.

Resetting to Factory Defaults

2.3
Note:
Remove Power from the Skyroute CL3050; disconnect battery and control
panel if applicable (mode 1).
Disconnect all wiring from the YEL and GRN terminals.
Connect a jumper wire between the YEL and GRN terminals.
Apply power to the system.
Note:
Remove power from the system.
Note:
Reconnect all original wiring and reapply power to the system.
Test System - Refer to Section 2.2
DO NOT connect the battery to the flying leads and AC or DC power
to the terminal strip until all other wiring connections are completed.
Resetting to factory defaults is required to change mode of operation.
When the hardware default has been completed; the yellow, green
and red LEDs will flash on and off continuously.
To resume communications with Connect 24, Section [11], Option 6
must be set to ON. To do this; the system must be powered up in pro-
gramming mode. Refer to Section 5 System Programming.