2 Installation, Testing & Factory Defaults
2.1

Installation

1
Determine The Operating mode required (see section [03])
The operating mode (modes 1, 2, or 3) will determine how the unit is to be wired
up. Refer to section 6, Programming Descriptions, section [10] for available
options and for programming defaults.
2
Determine the Mounting Location
Select a mounting location in a dry, protected area. The mounting location
should be positioned so that it is at least 30 cm. away from physical contact with
any person.
Note: Do Not exceed the following recommendations for wire run distances
Keybus and zone wiring should be run using minimum 22 gauge quad
(0.5mm). Two pair twisted is preferred.
a keypad, PC5108, or zone wiring can not exceed 1,000'/305m (in wire
length) from the Skyroute CL3050.
Shielded wire is not necessary unless wires are run in an area that may present
excessive RF noise or interference.
Refer to section 6, Programming Descriptions, section [10] for zone wir-
ing details.
Note:
3
Checking Signal Strength
Remove front cover
Connect Battery to the RED and BLK flying leads.
Connect AC Power source or 12 V
Allow unit to power up
Note:
When the green LED stops flashing, press and release the enroll button.
Ensure that Radio Signal Strength Indication (RSSI) is greater than the mini-
mum acceptable level as indicated below. If the signal level is not accept-
able, reposition and retest the Skyroute CL3050 until an acceptable signal
strength is found.
Red LED
On
On
On
On
On
Flash
4
Route Wiring to Mounting Location
Route wiring from the hardwired zones or control panel as required.
Note:
2 Installation, Testing & Factory Defaults
Generally, the higher the location and the closer that the Skyroute
CL3050 is to an outside wall, the better the signal strength will be.
The unit does not need to be enrolled with Connect 24 to check sig-
nal strength.
Yellow LED
On
On
On
Flash
Off
Off
*Minimum recommended signal strength for enrollment
Route wiring through conduit to a junction box if possible. Mount the
Skyroute Panel.
to RED & BLK terminals.
DC
Green LED
On
Flash
Off
Off
Off
Off
3
Signal Strength
>87%
69-87%
*52-68%
34-51%
16-33%
0-15%

Advertisement