DSC Skyroute CL3050 Installation & Programming Manual

Standalone wireless communicator compatible with all powerseries keypads

Advertisement

Quick Links

Standalone Wireless Communicator
Compatible with all PowerSeries keypads
Installation & Programming Guide
WARNING: This manual contains information on limitations
regarding product use and function and information on the limi-
tations as to liability of the manufacturer. Read the entire manual
carefully.

Advertisement

Table of Contents
loading

Summary of Contents for DSC Skyroute CL3050

  • Page 1 Standalone Wireless Communicator Compatible with all PowerSeries keypads Installation & Programming Guide WARNING: This manual contains information on limitations regarding product use and function and information on the limi- tations as to liability of the manufacturer. Read the entire manual carefully.
  • Page 2 Skyroute CL3050 Quick Start: Note: Before you start, you must be enrolled with CONNECT 24 as an authorized installer to activate a Skyroute transceiver. Enrollment is Free! If you are not already enrolled, call 1-888- 955-5583 in Canada or 1-888-251-7458 in the U.S. at least 24 hours before your first activation.
  • Page 3 For Your Records Location Test Time & Day Additional Notes CONNECT 24 Enrollment Information Note: Only authorized dealers can enroll a wireless system to Connect 24. Dealer application forms and additional information on the Connect 24 Voice Response Unit can be found at the Connect 24 web site. http://www.connect24.com/dealer.htm The information required for activation is listed below.
  • Page 4 Limited Warranty DSC warrants that for a period of one year from the date of purchase, the product shall be free of defects in material and workmanship under normal use and that in fulfillment of any breach of such warranty, DSC shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot.
  • Page 5: Table Of Contents

    Zone 3-8 Definitions ....................9 [03] Zone 1-2 Loop Response ..................9 [10] Skyroute CL3050 Mode of Operation..............9 [11] Skyroute CL3050 Configuration Options 1 ............10 [12] Skyroute CL3050 Configuration Options 2 ............11 [13] Skyroute CL3050 Trouble Output Mask ..............11 [15] System Time ......................13 [16] System Day ......................13...
  • Page 7: Section 1: Introduction

    Programming Mode If the Skyroute CL3050 detects a keypad on power up it will go into the program- ming mode. Programming mode allows the installer to custom program system options. Refer to Section 5, Programming Descriptions; and Section 6, Program- ming Worksheets for programming options and default settings.
  • Page 8: Specifications

    Skyroute CL3050 Standalone Wireless Communicator 1.1 Specifications • Power Supply Voltage ..................9-12 V or V Current ..................500 mA (Max) Low DC Trouble ..................8.8 V Low DC Restore ..................9.0 V Low AC Trouble ..................7.5 V Low AC Restore ..................8.0 V •...
  • Page 9: Section 2: Installation, Testing & Factory Defaults

    Ensure that Radio Signal Strength Indication (RSSI) is greater than the mini- mum acceptable level as indicated below. If the signal level is not accept- able, reposition and retest the Skyroute CL3050 until an acceptable signal strength is found. Red LED...
  • Page 10: Testing

    Enroll Unit Call Connect 24 and Enroll the Skyroute CL3050. Refer to page (ii) for contact information and a list of information required to complete the enrollment with the Connect 24 Voice Response Unit.
  • Page 11: Section 3: Controls & Indicators

    3 Controls and Indicators 3 Controls and Indicators Figure 2 Antenna Mounting Holes Green LED Yellow LED Red LED Battery (6 V ) Enroll Button Wire Access Tamper Switch 3.1 LED Indicators (see figure 2) Yellow LED During normal operation, the yellow LED will indicate the system status with a series of flashes as indicated below.
  • Page 12: Enroll Button

    Refer to Section 2 Step 3. 3.2 Enroll Button (see figure 2) The Skyroute CL3050 Enroll button is located on the outside of the plastic hous- ing directly below the status LEDs. The enroll button performs three functions. •...
  • Page 13: Section 4: Power Up Sequence

    The installer can then change this information if required. During power up, the Skyroute CL3050 will look for a keypad on the Keybus, if one is found, it will go into programming mode. If no keypad is found, it will look for a PC5108 zone expander module.
  • Page 14: Section 5: System Programming

    Section 1.1 Specifications. Note: Power down the Skyroute CL3050 when connecting or removing other Keybus modules from the system. If the Skyroute CL3050 is con- nected to a control panel (mode 1), the control panel must also be powered down.
  • Page 15: Section 6: Programming Descriptions

    Modes 2, 3 [01] Zone 1, 2 Definitions When the Skyroute CL3050 is in Mode 2 or 3, there are 14 options that can be programmed as zone types. All of the zone types with the exception of 00 (null zone) and 13 (TLM monitor) are straightforward.
  • Page 16: Skyroute Cl3050 Configuration Options 1

    BLK terminals is required when using this mode. The Programming sections will allow the installer to change the default zone types and attributes. The Skyroute CL3050 will continu- ously monitor these zones and transmit any alarms that occur to the central station.
  • Page 17: Skyroute Cl3050 Configuration Options 2

    All Modes This option is set automatically during the enrollment procedure with Connect 24. IF the Skyroute CL3050 is reset to the default settings this option must be set to ON for the Skyroute CL3050 to resume communications. Default - Not Enrolled.
  • Page 18 This trouble will be indicated if no acknowledgement has been received from Connect 24 after three attempts. Default - ON Option 8 - Skyroute CL3050 Tamper All Modes This trouble will be indicated if the cover is removed from the Skyroute CL3050 activating the on-board tamper switch. Default - OFF...
  • Page 19: System Time

    All Modes [18] Test Transmission Day When the Skyroute CL3050 is powered up for the first time, or after a default, it will check if the test transmission time and day are programmed. If they are not, a random day (Sunday-Saturday) will be programmed into this location. The Sky- route CL3050 will randomly generate this value.
  • Page 20 OFF and Option [3] must be set to ON; In Section [13], Option 3 must be set to ON and the Skyroute CL3050 must be operating in mode 2 or 3. Option 3. Default - OFF, Option 4. Default - OFF...
  • Page 21: System Event Communication Options

    Default - ON. Option 3 - Skyroute CL3050 Tamper All Modes Removing the cover on the Skyroute CL3050 will send a tamper reporting code to Connect 24. Default - OFF. Option 4 - PC5108 Module Fault Mode 3 Indicates a Keybus communications fault condition.
  • Page 22: Section 7: Programming Worksheets

    Default Default I___I___I Zone 1 05 I___I___I Zone 2 [10] Skyroute CL3050 Mode of Operation Default I___I___I 01 - Bell Follower, 02 - 2 Zone, 03 - 8 zone (PC5108 ) [11] Skyroute CL3050 Configuration Options 1 Default Option On...
  • Page 23 7 Programming Worksheets [13] Skyroute CL3050 Trouble Mask Default Option On Option Off I___I Low Battery Disabled I___I Input Supply Failure Disabled I___I Zone Fault/Tamper (DEOL only) Disabled I___I No Service Available Disabled I___I Radio Failure Disabled I___I PC5108 Failure...
  • Page 24 [21] System Event Communication Options Default Option On Option Off I___I Input Supply Failure Disabled I___I Low Battery Disabled I___I Skyroute CL3050 Tamper Disabled I___I PC5108 Module Fault Disabled I___I PC5108 Tamper Disabled I___I 6-8 For Future Use [22] Input Supply Fail TX Delay...
  • Page 25: Glossary Of Terms

    System Identification Number - ID Number of the Cellular provider Mobile Identification Number - The 10 digit decimal number used for registrations and pages (the phone number of the Skyroute CL3050). Page A transmission that is sent from the Cellemetry Gateway to the Cel-...
  • Page 26: Appendix A

    Skyroute CL3050 Standalone Wireless Communicator Appendix A: Reporting Codes Events Reporting Codes Events Reporting Codes Contact Contact Zone Alarms Zone Restores Burglary Zone BAXX E130 Burglary Zone BHXX R130 Fire Zone FAXX E110 Fire Zone FHXX R110 Panic Zone PAXX...
  • Page 27 Generic Panic Zone PA98 E120 Low Battery Trouble YT00 E302 Generic Supervisory UA98 E140 Low Battery Restore YR00 R302 Skyroute CL3050 TA00 E137 Tamper Alarm Skyroute CL3050 TR00 R137 Tamper Restore PC5108 Tamper Alarm TA00 E330 PC5108 Tamper Restore TR00...
  • Page 28 ©2002 Digital Security Controls Ltd. Toronto • Canada • 1-800-387-3630 www.dsc.com Printed in Canada 29034531r001 Forward comments about this manual to: pubs@dsc.com...

Table of Contents