C. Convection Blower Replacement
Follow the proper shut down procedures as outlined on
page 22, Section 4.A.
Removal of Cast Sides
You will need to remove the cast sides in order to remove
and replace the convection blower.
1. There is a latch on the back side of the cast side in the
middle of the top opening of the cast side as indicated
in Figure 33.1.
2. Place your fingers inside the opening and squeeze
the latch. The side can now be pulled toward you and
removed. Place on a protective surface so as not to
damage the finish.
3. To replace the side, set the bottom in first. Squeeze
the latch in an open position. Place the cast side into
position and then release the latch. The latch hooks
onto a bracket to hold the side in place.
Figure 30.1

Convection Blower Replacement

1. After the sides are removed, reach behind the blower
and release the latch by pushing the top of the latch
towards the blower (Figure 33.2).
2. Rock the top of the blower slightly and lift up and out.
The blower will pass around the control board and out
the side of the appliance.
3. Disconnect the wire harness from the bottom of the
blower by depressing the tabs on the sides of the
connector and then pulling to remove (Figure 30.3).
4. Re-connect wire harness to the new replacement
blower. Install the blower by placing the bottom flange
into the opening first then rotate blower up into position.
5. When the blower is properly positioned the latch will
engage the notch to hold the blower in place (Figure
33.4).
August 13, 2018
Location of Latch for
Removing Cast Sides
7036-187M
Notch
Figure 33.2
Convection
Blower
Figure 33.3
Latch Engaged
Figure 33.4
MT. VERNON AE INSERT
Latch
Disconnect Wire Harness
from Bottom of Blower
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents