I. Fire Characteristics & Flame Height
Adjustment
(Feed Rate) A properly adjusted fire will have an active
flame pattern and the flame will rise and fall somewhat.
This is normal.
On HIGH setting, the flame will extend approximately 8
inches (203mm) out of the fire pot. If it is not 8 inches
(203mm) tall, increase the flame height.
On MEDIUM or LOW setting the flame will be shorter.
Reduce the flame height if the fire has tall flames with
black tails and seems somewhat lazy. This may also
indicate that the fire pot and/or heat exchanger needs
to be cleaned. Refer to Section 4 for Maintenance and
Cleaning Instructions.
Adjusting the Flame Height (Feed Rate)
Set your appliance to "MANUAL" mode on the wall
control.
Set the heat output level to HIGH.
Adjust the flame height using the "FLAME HEIGHT
ADJUST" screen on the wall control (Figure14.1).
Figure 14.1
J. Clear Space
Mantel: Avoid placing candles and other heat-sensitive
objects on mantel or hearth. Heat may damage
these objects.
NOTICE: Clearances may only be reduced by means
approved by the regulatory authority having
jurisdiction.
WARNING
Fire Risk.
Do NOT place combustible objects in front of
the appliance. High temperatures may ignite
clothing, furniture or draperies. Maintain a
minimum clearance of 3 feet (914mm) in front
of appliance.
WARNING
Fire Risk.
Do NOT operate appliance:
With appliance door open
With fire pot floor open
With ash pan removed
14
Fire Risk.
Keep combustible materials, gasoline and other
flammable vapors and liquids clear of appliance.
Do NOT store flammable materials in the appliance's
vicinity.
DO NOT USE GASOLINE, LANTERN FUEL,
KEROSENE, CHARCOAL LIGHTER FLUID OR
SIMILAR LIQUIDS TO START OR "FRESHEN UP"
A FIRE IN THIS APPLIANCE.
DO NOT BURN GARBAGE OR FLAMMABLE
FLUIDS SUCH AS GASOLINE, NAPHTHA OR
ENGINE OIL.
DO NOT USE CHEMICALS OR FLUIDS TO START
THE FIRE.
Keep all such liquids well away from the appliance
while it is in use.
Combustible materials may ignite.
K. Optional Battery Back-up System
Hook up to battery terminals BEFORE you plug
battery into appliance.
Damage to internal electronic components may
occur.
The appliance has been designed to operate on an optional
battery back-up system.
If you have frequent power outages in your region, hook
the appliance up to a 12 volt battery and it will automatically
switch to battery power in the event of a power failure. The
12 volt power cord, sold as a separate accessory, does not
charge the battery.
Risk of Injury!
Blowers may continue to run and would be
exposed to human contact.
7036-187M