Quadra-Fire MT VERNON Owner's Manual page 28

Pellet insert advanced energy ae
Table of Contents

Advertisement

MT. VERNON AE INSERT
a. It is necessary to remove the baffle to gain access
to the heat exchanger. Follow instructions for
BAFFLE REMOVAL on page 31.
b. Vacuum the ash from the heat exchanger with an
upholstery brush to remove the majority of the ash.
Be sure to vacuum the back of the baffle also.
Inspect the drop tube and remove any residue
build-up in the drop tube (Figure 28.2).
Figure 28.1 - Example of a dirty heat exchanger
Figure 28.2
c. Assemble the crevice tool from the micro cleaning
kit to attach to a Shop Vac (Figure 28.3).
Figure 28.3
d. Use the crevice tool to finish cleaning the heat
exchanger fins. It is critical that the 2 exhaust
exits at the back of the firebox floor (left and right)
be thoroughly cleaned (Figure 28.4). There are
several ways this can done.
-
Use the crevice tool.
-
Attach a hose 1/2 inch (12.7mm) in diameter and
approximately 2 feet (607mm in length to your
vacuum hose.
-
Use a bottle brush and push the ash down to the
bottom. Remove the combustion (exhaust) blower
and then vacuum out the ash.
2 exhaust exits (left and right side) must
be thoroughly cleaned. Each exit is
approximately 4 inches wide, 1 inch
Figure 28.4
across and 3 inches deep.
28
NOTE: It is normal to see a certain amount of wear of
the heat exchanger fins. You may notice some
flaking and pitting on some of the pins. The heat
exchanger system will function as designed with
as many as 15 of these pins missing.
e. Removing the Combustion (Exhaust) Blower
-
The combustion blower is mounted in the bottom
right rear of the appliance (Figure 28.5).
-
Remove side panel and then using an 11/32 nut
driver to loosen all six nuts, but do not remove.
Rotate the blower and remove from the housing
(Figure 28.6).
-
Set the blower on the top of the housing. You do
not need to disconnect the wires.
Vacuum out the exhaust area (Figure 28.7).
-
Figure 28.5
Loosen all 6 nuts, but do NOT Remove
Figure 28.6
Figure 28.7
7036-187M
Vacuum out the exhaust area.