Siemens S7-1200 System Manual page 543

Hide thumbs Also See for S7-1200:
Table of Contents

Advertisement

ERROR
STATUS
(DW#16#...)
0
00700200
1
C08xyy00
1
C0808000
1
C0808100
1
C0808200
1
C0808300
1
C0808400
1
C0808600
1
C0808700
1
C0808800
1
C0808900
1
C0808A00
1
C0808B00
1
C0808C00
1
C0808D00
1
C0808E00
1
C0808F00
1
C0809000
1
C0809100
1
C0809400
1
C0809500
1
C080C200
1
C080C300
1
C080C400
1
C080D200
S7-1200 Programmable controller
System Manual, 03/2014, A5E02486680-AG
Description
Intermediate call (REQ irrelevant)
General failure
LADDR parameters for identification of the interface are invalid.
LADDR parameters for identification of the interface have been assigned a non-
supported hardware interface.
CONF_DATA parameter error: Data type of the Variant pointer does not match the data
type Byte.
CONF_DATA parameter error: The area pointer is not in the DB of the Variant pointer.
CONF_DATA parameter error: The Variant pointer is the wrong length.
Reserved
Inconsistency in the CONF_DATA data block length to the IP configuration
The parameters of the CONF_DATA data block field_type_id are invalid. (Only
field_type_id = 0 is allowed.)
The parameters of the CONF_DATA data block field_type_id are invalid or have been
used several times.
LEN length of the IP configuration parameters or subfield_cnt errors
The IP configuration ID parameter is invalid or unsupported.
The Sub-block of the IP configuration is incorrectly placed (Sub-block wrong, wrong
order, or used multiple times).
The length of a statement LEN Sub-blocks is invalid.
The value of the parameter in Sub-blocks mode is invalid.
Sub-block conflict between the IP configuration and a previous Sub-block.
The parameters of the subfield are write-protected (for example: parameters are
specified by configuration, or PNIO mode is enabled).
Reserved
A parameter in the Sub-block IP configuration has not been defined or may not be
used.
There is an inconsistency between a parameter of the Sub-block IP configuration and
other parameters.
Instruction cannot be executed. This error can occur if, for example, communication
with the interface has been lost.
There are not enough resources. This error can occur if, for example, the instruction is
called multiple times with different parameters
Communication failure. The error can occur temporarily and will require a repeat of the
user program.
Execution of the instruction is not supported by the PROFINET interface.
Communication
10.2 PROFINET
543