Ventilation Clearance

To ensure proper ventilation to the CR500 printer, maintain minimum clearance distances, as
shown in the following illustrations.
Ventilation holes are provided for the cooling fans at the bottom and sides of the print unit. Install
the printer so that the sides are at least 7.9 inches (200 mm) away from the surrounding wall.
Keep the back of the printer at least 3.9 inches (100 mm) away from a wall. Do not place any
objects on top of the printer.
Side Clearance
Back Clearance
CR500 Instant Issuance System Installation and Administrator's Guide
11