8.3.2. IGBT module, V1

IGBT module can be tested by multimeter if using the diode tester function. Module holds six diodes and in many
cases they may be defective if IGBT is damaged
When measuring IGBT unit diodes you must disconnect other end of main transformer (X7)
After measuring connect other end (X7) back
o
Measurings:
1) Negative test pole (1, black) to connector X19, positive test pole (1, red) to connectors X13, X14 and X17 one at time
Result: 0,3...0,6 diodes Ok
2) Positive test pole (2, red) to connector X20, negative test pole (2, black) to connectors and X13, X14 and X17 one at time
Result: 0,3...0,6 diodes Ok