8.2.2. IGBT module, V2

IGBT module can be tested by multimeter if using the diode tester function. Module holds four diodes and in many
cases they may be defective if IGBT is damaged
When measuring IGBT unit diodes you must disconnect other end of main transformer (X7)
After measuring connect other end (X7) back
o
Measurings:
1) Positive test pole to connector X7 and X8 one at time, negative test pole to DC link (+)
Result: 0,3...0,6 diodes Ok
2) Positive test pole to DC-link (-), negative test pole to X7 and X8 one at time
Result: 0,3...0,6 diodes Ok
Kemppi Oy
SERVICE MANUAL
KEMPACT RA_V_1.2
32 (40)