8.3. Kempact 253MV, 323MV
8.3.1. Primary rectifier, V31
Primary side primary rectifier diodes can be measured one at the time
•
Diodes must be measured both forward bias and reverse bias condition to make sure they are fine
•
Check the diodes using the multimeter diode function to measure their threshold voltage 0,3...0,6 V
•
Measurings :
1) Negative test pole to rectifier pole (1, black), positive test pole to rectifiers poles (1, red) one at time
Result: 0,3...0,6 diodes Ok.
2) Positive test pole to rectifier pole (3, red), negative test pole to rectifier poles (2, black) one at the time
Result: no value diodes Ok
3) Positive test pole to rectifier pole (2, red), negative test pole rectifier poles (2, black)one at the time
Result: 0,3...0,6 diodes Ok
4) Negative test pole to rectifier pole (3, black), positive test pole to rectifier poles (2, red) one at the time
Result: no value diodes Ok