8.2. Kempact 253, 323

8.2.1. Primary rectifier, V1

Primary side primary rectifier diodes can be measured one at the time
Diodes must be measured both forward bias and reverse bias condition to make sure they are fine
Check the diodes using the multimeter diode function to measure their threshold voltage 0,3...0,6 V
Measurings:
1) Positive test pole to DC-link (-), negative test pole to L1, L2, L3 (one at the time)
Result: 0,3...0,6 diodes Ok
2) Positive test pole to DC-link (+), negative test pole L1, L2, L3 (one at the time)
Result: no value diodes Ok
3) Negative test pole to DC-link (+), positive test pole L1, L2, L3 (one at the time)
Result: 0,3...0,6 diodes Ok
4) Negative test pole to DC-link (-), positive test pole L1, L2, L3 (one at the time)
Result: no value diodes Ok
Kemppi Oy
SERVICE MANUAL
KEMPACT RA_V_1.2
V1
31 (40)