Solar Settings - Salus Multi-Mix Operation And Installation Manual

Weather controller
Table of Contents

Advertisement

Time
of
the
automatic
pump
blocking
Messages
Reaction on
stabilization,
vacation mode
Frost protection

Solar settings

Name
Mode
Delta T pump
activation
Delta T pump
deactivation
Minimum collector
temperature
Maximum collector
temperature
Collector
deactivation
temperature
Minimal pump
rotations
Frost protection
mode - solar
DHW maximum
temperature
Night cooling
0...60
0min
ON, OFF
ON
Night temp
Frost
protection
mode
mode
Range
Settings
OFF, ON
ON
1,5...20
7°C
1...19
3°C
4...110
10°C
110...150
120°C
115...200
150°C
15...100
15%
0°C
-15...-35
25...90
55°C
Function saving electricity by stopping the pump of the regulated
heating circuit when the measured temperature of the circulating
water is maintained for 15 minutes above the preset temperature
water. Recommended setting: 15 min.
OFF – allows you to display informational messages in the main
window.
ON – does not allow the display of informational messages in the
main window.
This parameter determines whether the Holiday mode and OFF
mode is total off heat receiver (frost protection mode) or the
temperature is maintained at night.
OFF – disables operation of solar circuit,
ON – enables operation of solar circuit.
When difference between solar collector temperature and the
lower DHW temperature exceeds Delta T pump activation
parameter value, solar pump will be activated.
When difference between solar collector temperature and lower
DHW temperature drops below Delta T pump deactivation
parameter value, solar pump will be deactivated.
Solar pump will not be enabled below this temperature. If
Minimum collector temperature = OFF, function is disabled.
Above this temperature, solar pump will be enabled in order to
cool the solar panel provided that HUW tank temperature is lower
than the maximum value. If Maximum collector temperature =
OFF, function is disabled.
Above this temperature, solar pump will be disabled in order to
prevent it against overheating. Pump will be enabled again after
the solar panel is cooled down. If Collector deactivation
temperature = OFF, function is disabled.
If Minimum pump rotations = OFF, solar pump revolutions
modulation function is disabled (pump always activates with 100%
revolutions).
If Minimum pump rotations > 0, solar pump revolutions modulation
function is enabled. Function enables to increase reception of
heat energy from the solar panel at low insolation. Solar pump
decreases its revolutions when difference between temperatures
between a solar collector sensor and DHW tank lower
temperature drops.
Solar panel temperature at which frost protection mode is
activated. This value should be higher than freezing temperature
of the agent inside a solar circuit, e.g. glycol. Solar pump is
activated when solar panel temperature drops below Frost
protection mode - solar parameter value. It causes heat reception
from DHW tank and heating the solar panel. Caution: enabling this
function can cause considerable heat energy losses. When Frost
protection mode – solar = OFF, frost protection mode of the solar
is disabled.
Maximum preset temperature of water in the tank. This parameter
defines what temperature the DHW tank will be heated up to
during the solar collector is loaded. It is a very important
parameter because if it is too high, there could be a risk of burning
with utility water. In case of installations with solar system, too low
value will limit heat gains because solar pump loads the DHW tank
to DHW maximum temperature. During designing a DHW system,
a possibility of regulator fault should be taken into consideration.
As a result of such failure, water inside the DHW tank can be
heated up to a temperature which is dangerous for users.
Therefore, additional protection should be used in a form of
thermostatic valves.
The controller activates night cooling from 0:00 a.m. to 5:00 a.m.
During this time the regulator will start the collector pump in order
to discharge the DHW tank to the set temperature. Regardless of
the conditions, the controller will exit the cooling mode at 5:00 a.m.
and will go to normal control. Setting Night cooling = OFF disables
the function.
36