cables secured from splitting should be connected to screw terminals of the (6) connector.
cables should be put through cable outlets in the casing (1) and secured from ripping or
loosening by a holdfast (5) – break it out from the casing. Zabezpiecza to przewody przed
wyrwaniem oraz obluzowaniem.
it is not allowed to coil excess of the cable and to leave not connected leads inside the casing
of the regulator.
Connecting wires to the controller terminals: 1 – connector, 2- protective strip, 3 - holdfasts placing (should be broken out
for the casing), 4 - cable outlets, 5 - improper cable connection, 6 - holdfast of the cable.
Electrical cables should be isolated from hot parts of the boiler, especially from flues.
When the cables connection is done the cover of the connectors has to be put in place.
The connectors cover should be always screwed on to the casing of the regulator. Apart
from providing safety for the user, the connectors cover also protects the interior of
the regulator from hazardous environmental conditions providing a proper level of the
IP protection.