Controller assembly

Environmental conditions

Due to fire risk it is forbidden to use the
controller in proximity of explosive gases or
dust. Moreover the controller cannot be used
in conditions of water steam condensation or
be exposed to effects of water.
Storage and transport
conditions
The
controller
cannot
immediate effects of atmospheric conditions
i.e. rain or sunrays. Temperature of storage
and transport should be within scope
-15...+65°C.

Mounting requirements

Regulator should be installed by qualified and
authorized technician with observance of
applicable standards and regulations.
The manufacturer disclaims any liability for
damage
caused
instructions specified in this manual.
Ambient temperature and temperature of
mounting base should be within the range of
0...50˚C.
Prior to installing the controller make sure that
it will properly cooperate with hydraulic and
electrical system.

Module installation

The regulator should be screwed on to the flat
horizontal or vertical surface (e.g. boiler
housing,
room
wall). To
regulator use mounting holes and proper
screws. Location and spacing of mounting
holes are shown in the picture below.
The regulator must not be used
as a free-standing device.
be
exposed
by
non-observance
screw
on
After installation make sure that the device is
properly mounted and it is impossible to
detach it from the mounting surface.
The
regulator
protection
connectors cover side provides IP00 rating,
and because of that connectors must be
unconditionally covered with the cover.
If there is a need to gain an access to the
terminals side, it is a must to disconnect the
mains voltage and make sure there is no
to
dangerous voltage on regulator terminals.
The
controller
temperature sensor type CT-10, CT6-P, CT6-
W. The use of other sensors is prohibited.
At least one heating circuit temperature
sensor and one external temperature sensor
(weather sensor) are necessary to activate
the controller.
Caution: the controller is equipped
of
with various types of temperature
sensors!
inappropriate
incorrect operation of the controller!
Sensors for heating circuits
Direct
heating
installed in a hydraulic coupling. If there is no
hydraulic coupling in the system, it can be
fixed to a supplying pipe coming out of the
heat source (from boiler).
Assemble
the
sensor on a pipe after the heating circuit
pump.
external surface of the pipe with the use of
thermal
together with the pipe.
Mounting temperature sensor: 1 - pipe, 2 – clamps, 3 -
thermal insulation, 4 - temperature sensor.
14
casing provides the
rating.
The
casing

Temperature sensors assembly

cooperates
Connecting
sensor
circuit
sensor
the
adjustable
heating
Insulate sensors affixed to the
insulation
covering
IP20
on
the
solely
with
an
will
cause
should
be
circuit
the
sensor

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents