Hydraulic scheme no. 8 - diagram "B" with heat buffer with layered charging buffer
1 – boiler
2 – heat buffer
3 – additional heat source (fireplace)
4 – controller
5 – boiler pump
6 – HUW pump
8 – H1 circuit pump
9 – H2 circuit pump
10 – valve electrical servo of adjustable circuit (H2)
PROPOSED SETTINGS:
Parameter
Hydraulic diagram
Pump start temperature
Mode
Minimum temperature
Selection
Temperature deactivating main
heat source
Pump start temperature
DHW mode
8
Shown hydraulic diagram does not replace a central heating system and can be used only for demonstrative purposes
Setting
8
menu→ service setting → System
25C
menu→ service setting → System
menu→ service setting → System→ Main heat source
ON
40C
menu→ service setting → System→ Main heat source
ON
menu→ service setting → System→ Main heat source
35C
menu→ service setting → System→ Main heat source
55C
menu→ service setting →System→Additional heat source
ON
menu→ service setting → HUW settings
26
11 - DHW circulating pump
12 - solar panel
13 - solar pump
H1-S – upper sensor temperature buffer
WS - weather sensor
DHW – DHW tank temperature sensor
SH - collector solar temperature sensor
SL - lower temperature sensor DHW tank (lower solar
sensor).